Setting The Engineering Units - Flowmetrics 922-MFC Installation And Operating Instructions Manual

Table of Contents

Advertisement

Heat - Gas:
compensated Mass flow as well as Heat flow. The resulting Heat flow
is displayed in Btu/h (kW, kcal/h, MJ/h) and totalled in Btu (kWh,
kcal, MJ).
Heat - Steam:
yield a compensated Mass flow as well as Heat flow. The resulting
Heat flow is displayed in Btu/h (kW, kcal/h, MJ/h) and totalled in
kBtu (kWh, kcal, MJ). (Unit may be set up to follow saturated steam
curve, see page 3-12)
Heat - Liquid:
sated Mass flow as well as Heat flow. The resulting Heat flow is
displayed in Btu/h (kW, kcal/h, MJ/h) and totalled in kBtu (kWh,
kcal, MJ).
Del Heat - Liquids:
compensated Mass flow as well as Heat flow. The resulting Heat flow
is displayed in Btu/h (kW, kcal/h, MJ/h) and totalled in kBtu (kWh,
kcal, MJ).

3.6 Setting the Engineering Units

Engineering units establish the measuring system that is
used for entry and display of the parameters. There are
four selections available
To get to the Engineering menu . . .
Display shows
Run?
Set Computations?
Engineering Units?
English?
Uses volume, pressure and temperature to yield a
Uses volume and pressure and/or temperature to
Uses volume and temperature to yield a compen-
Uses volume and two temperatures to yield a
Press
A
A
ENT
A, B, C, or ENT
3-6