Cli Commands; Configuring The Connection Mode - Cisco CE 2000 Platform SCE 2000 4xGBE Installation And Configuration Manual

Cisco systems ce 2000 platform installation and configuration guide
Hide thumbs Also See for CE 2000 Platform SCE 2000 4xGBE:
Table of Contents

Advertisement

Chapter 6
Cabling the Line Ports and Completing the Installation
Step 11

CLI Commands

This section presents CLI commands relevant to the configuration and monitoring of a redundant
system.
Use the following commands to configure and monitor a redundant system:
Topology-Related Parameters for Redundant Topologies
All four of the topology-related parameters are required when configuring a redundant topology.

Configuring the Connection Mode

Use the following command to configure the connection mode, including the following
parameters:
OL-7824-02
You can now start working with the Subscriber Manager.
connection-mode
[no] force failure-condition
Show interface linecard 'number' connection-mode
Show interface linecard 'number' physically-connected-links
Connection mode: Redundancy is achieved by cascading two SCE 2000 platforms. Therefore
the connection mode for both SCE 2000 platforms may be either:
Inline-cascade
Receive-only-cascade
Physically-connected-links: For each of the cascaded SCE 2000 platforms, this parameter
defines the number of the link (Link 0 or Link 1) connected to this SCE 2000 platform.
Priority: For each of the cascaded SCE 2000 platforms, this parameter defines whether it is
the primary or secondary device.
On-failure: For each of the cascaded SCE 2000 platforms, this parameter determines whether
the system cuts the traffic or bypasses it when the SCE 2000 platform either has failed or is
booting.
inline/receive only
physically connected links
behavior upon failure of the SCE 2000 platform
primary/secondary
SCE 2000 4xGBE Installation and Configuration Guide
Installing a Cascaded System
6-13

Advertisement

Table of Contents
loading

Table of Contents