Chapter 5
Connecting the Management Interfaces and Performing Initial System Configuration
On-Failure behavior: Determines the behavior of the SCE 2000 upon failure, or reboot. One
of the following link modes may be chosen for the SCE 2000 in the cases of failure or reboot:
Admin status after abnormal reboot: This parameter determines whether the SCE 2000
returns to full operational mode after abnormal (not user-requested) boot, or stays in non-
operational mode, in which the SCE 2000 behaves as in failure mode. This parameter can be
set to one of the following:
The procedure described below is a presentation of all the questions in the topology configuration.
In actual practice, all questions may not be presented for a particular configuration, depending on
the topology deployed.
Study the examples that follow to understand the procedure for various topologies.
To configure topology dependent parameters, complete the following steps:
Step 1
Would you like to enter the Topology configuration menu? [no]: y
Type y and press Enter.
The topology configuration dialog begins.
Step 2
Enter Connection mode:
1- inline
2- receive-only
Enter your choice [1]:
Step 3
Is this a cascade deployment? [no]:
Step 4
Enter Physically connected link:
0- link-0
1- link-1
Enter your choice [0]:
Step 5
OL-7824-02
Secondary
Bypass: traffic is bypassed using the internal bypass card.
Cutoff: the link is forced down.
Operational
Non-operational
Enter the topology configuration menu.
Specify the connection mode.
To define inline connection mode, press Enter.
To define receive-only connection mode, type 2 and press Enter.
Specify the deployment type.
To specify a Single-SCE Platform deployment, press Enter.
To specify a Cascade deployment, type y and press Enter.
Specify the physically-connected-link index.
To specify link-0, press Enter.
To specify link-1, type 1 and press Enter.
Specify the SCE 2000 priority.
SCE 2000 4xGBE Installation and Configuration Guide