Important Message; Important Information On The Gi29L; Before You Start; For Your Safety - Regency Fireplace Products Gi29L-NG Owners & Installation Manual

Gas insert
Table of Contents

Advertisement

owner's information
ImportantMessage
SAVE THESE INSTRUCTIONS
The Gi29 gas insert must be installed in accordance
with the instructions in this manual; carefully read
them. Consult the authority having jurisdiction in
your area to determine the need for permits prior
to starting the installation. It is the responsibility
of the installer to ensure this fireplace is installed
in compliance with the manufacturer's instructions
and all applicable codes.
ImportantInformationon
theGi29L
OnDemandPilot(SevenDaySafetyTimer).
Approved for use in Canada and the USA.
This appliance is a millivolt standing pilot system
fitted with the on demand pilot, a safety feature
that shuts down the gas valve by extinguishing the
pilot light after seven days of inactivity. Each time
the main burner shuts down, manually or through a
call from the thermostat, the seven day timer starts
again. While on these standing pilot systems, the
control valve is adjusted manually and the seven-
day inactivity timer is managed by a circuit board.
If the pilot light extinguishes after seven days of
inactivity, the control knob will remain in the ON
position. The pilot cannot be lit again until the
control knob is manually returned to the OFF
position. If the unit never goes as long as seven
days without a call for heat, the pilot will remain lit
until it is manually shut off. See the instructions in
this manual and on the appliance's lighting
instructions plate to light or relight the pilot.
BeforeYouStart
We are required by the Canadian Safety Standards
and ANSI Standards to make you aware of the
following.
INSTALLATION AND REPAIR SHOULD
BEDONEBYANAUTHORIZEDSERVICE
PERSON.THEAPPLIANCESHOULDBE
INSPECTED B EFORE U SE A ND A T L EAST
ANNUALLY BY A PROFESSIONAL
SERVICE PERSON. MORE FREQUENT
CLEANING MAY BE REQUIRED DUE
TOLINTFROMCARPETING,BEDDING
MATERIAL, ETC. IT IS IMPERATIVE
THAT CONTROL COMPARTMENTS,
BURNERS, AND CIRCULATING AIR
PASSAGEWAYS OF THE APPLIANCE
ARE KEPT CLEAN.
10
| Gi29 Direct Vent Gas Insert
WARNING: FAILURE TO INSTALL THIS
APPLIANCE CORRECTLY WILL VOID
YOUR WARRANTY AND MAY CAUSE
A SERIOUS HOUSE FIRE.
DUE TO HIGH TEMPERATURES, THE
APPLIANCE SHOULD BE LOCATED
OUT OF TRAFFIC AND AWAY FROM
FURNITURE AND DRAPERIES.
CHILDRENANDADULTSSHOULDBE
ALERTEDTOTHEHAZARDSOFHIGH
SURFACE TEMPERATURES, ESPE-
CIALLYTHEFIREPLACEGLASS,AND
SHOULDSTAYAWAYTOAVOIDBURNS
OR CLOTHING IGNITION.
A BARRIER DESIGNED TO REDUCE
THERISKOFBURNSFROMTHEHOT
VIEWING GLASS IS PROVIDED WITH
THIS APPLIANCE AND SHALL BE
INSTALLED FOR THE PROTECTION
OF CHILDREN AND OTHER AT-RISK
INDIVIDUALS
CLOTHING OR OTHER FLAMMABLE
MATERIALSHOULDNOTBEPLACED
ON OR NEAR THE APPLIANCE.
IFTHEBARRIERBECOMESDAMAGED,
IT MUST BE REPLACED WITH THE
MANUFACTURER'S BARRIER FOR
THIS APPLIANCE.
ANY SAFETY SCREEN, GUARD,
O R  B A R R I E R  R E M O V E D  F O R
SERVICING AN APPLIANCE
BEREPLACEDPRIORTOOPERATING
THE APPLIANCE.
ForYourSafety
This appliance requires air for proper combustion.
Always provide adequate combustion and ventilation
air. Follow instructions and information in CAN/CGA
B149 (in Canada) or the National Fuel Gas Code
ANSI Z223.1 (in the USA), regarding requirements
for combustion and ventilation air.

Specifications

At pressures over 1/2 psig, the pipe to the unit
must be disconnected.
GasMax.InputCapacity:
Natural Gas
31,500 Btu/h (0-2000 ft/0-610 m)
(2,000-4,000 ft/610-1,370 m)
Propane
31,500 Btu/h
Min.Input
Natural Gas
17,000 Btu/h (0-2,000 ft/0-610 m)
(2,000-4,000 ft/610-1,370 m)
Propane
17,000 Btu/h
Fuels: Approved for use with natural gas and
propane. Approved as-is for use at 0' to 4,500'
(0-1,370 m).
Electrical: 120 V A.C. system.
Circulation Fan: Variable speed, 140 CFM.
Log Set: Ceramic fibre, 10 per set
Glass Crystals: 2-1/2 pounds of crushed glass
VentSystem: 3" (76 mm) co-linear aluminium flex
(intake & exhaust). The unit's thermal efficiency
rating is determined under continuous operating
conditions, independent of any installed system.
MUST
30,500 Btu/h
16,500 Btu/h