FanReplacement(ifOptionalFanKitisInstalled)
To access the side and rear panels, disconnect the gas and venting (see the venting and flue installation sections in this manual for steps). You cannot
access the blower from the front of the appliance.
1. Shut the power off.
2. From the back of the unit, remove the six screws, then lift the fan
mount plate up and out.
3. Remove the electrical access panel from the left side of the insert by
removing five screws.
Black/Noir
Black/Noir
4. Disconnect the green ground wire on the right side of the unit (refer to
wiring diagram).
S.I.T. Valve
(To/À THTP)
(To/À TH)
Cut here/Couper ici
(OPTIONAL REMOTE)
Receiver
Remote
ON
Neutral/Neutre
Live/
Green/Vert
Sous
tension
Black/
Noir
DC
SPARKER
5. Remove the fan from the mounting plate by removing four screws from
Green/
Vert
the outside of the fan access panel.
Red/Rouge
White/Blanc
To/À Thermocouple IN
OFF
Remote
6. To install, reverse these steps.