Fan Installation (Optional) - Regency Fireplace Products Gi29L-NG Owners & Installation Manual

Gas insert
Table of Contents

Advertisement

FanInstallation(optional)
Gi29 Fan Install
Fan installation must be done before installing the fireplace
insert.
1. Shut the power off.
2. Remove the safety screen.
3. From the back of the unit, loosen the three top screws and re-
move the three bottom screws, then lift the fan mount plate up
and out.
4. Attach the fan to the fan mount plate with the four supplied
screws.
Neutral/Neutre
Live/
Green/Vert
Sous
tension
ON
Black/
Noir
DC
SPARKER
Green/
Vert
Red/Rouge
White/Blanc
To/À Thermocouple IN
920-433c
Green/Vert
OFF
Black/
Noir
Black
Wire marked
''896''
Gas In/Entrée de gaz
5. a) From the rear, feed the thermodisc and wire to the front of the
fireplace. Connect the red connector from the Fan Controller Box
to the thermodisc. Attach the thermodisc onto the clip under the
valve tray by sliding into position from the front. Slide the thermo-
disc left to right into position.
To Fan Controller Box
b) If you cannot reach to the thermodisc location, the media
tray can be removed. Follow steps in the manual to remove the
burner tray. Remove the 10 screws that hold the media tray on
the valve tray. Once the tray has been removed, the thermodisc
can be installed.
1
6
Black
Wire marked
Grey Wire
ITEM
PART #
marked 811
1
904-153
2
904-330
3
904-612
4
904-169
5
910-692
6
N/A
1
1
4
2
2
3
5
DESCRIPTION
Star Lock Washer
8-32 Hex Nut
8-32 x 1/2" Ground Lug
#10 Split Lock Washer
Green Ground Wire
Power Cord Ground Wire
Gi29 Direct Vent Gas Insert |
installation
29
08/08/22

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gi29l-lp