Turn on the Appliance
With the system OFF, press the ON/
OFF Key on the Transmitter. The
Transmitter display will show some
other active Icons on the screen. At
the same time the Receiver will ac-
tivate the appliance. A single "beep"
from the Receiver will confirm recep-
tion of the command.
Smart Thermostat (Transmitter Operation)
Temperature indication Display
With the system in the "OFF" position, press the Thermostat Key and
The Smart Thermostat function adjusts the flame height in accordance
the Mode Key at the same time. Look at the LCD screen on the transmit-
to the difference between the set point temperature and the actual room
ter to verify that a C or F is visible to the right of the room temperature
temperatures. As the room temperature gets closer to the set point the
display (Figures 4 & 5).
Smart Function will modulate the flame down.
To activate this function, press the Thermostat Key (Fig. 1) until the word
"SMART" appears to the right of the temperature bulb graphic (Fig. 11).
Turn off the Appliance
To adjust the set temperature, press the Up or Down Arrow Keys until
the desired set temperature is displayed on the LCD screen of the
With the system ON, press the ON/OFF Key on the Transmitter. The
Transmitter (Fig. 12).
Transmitter LCD display will only show the room temperature (Fig. 6).
Note. When Smart Thermostat is activated, manual flame height adjust-
At the same time the Receiver will turn off the appliance. A single "beep"
ment is disabled.
from the Receiver confirms reception of the command.
Figure 4: Remote Control dis-
play in Farenheit.
Figure 11: Smart Flame Function
Turn on the Appliance
With the system OFF, press the ON/
Fan Speed Control**
OFF Key on the Transmitter. The
Transmitter display will show some
If the appliance is equipped with a hot air circulating fan, the speed of
other active Icons on the screen. At
the fan can be controlled by the Proflame system. The fan speed can be
the same time the Receiver will ac-
adjusted through six (6) speeds. To activate this function use the Mode Key
919-829
tivate the appliance. A single "beep"
(fig.1) to index to the fan control icon (Fig. 13). Use the Up/Down Arrow
from the Receiver will confirm recep-
Keys (fig.1) to turn on, off or adjust the fan speed (fig. 14). A single "beep"
tion of the command.
will confirm reception of the command.
Turn off the Appliance
With the system ON, press the ON/OFF Key on the Transmitter. The
Transmitter LCD display will only show the room temperature (Fig. 6).
At the same time the Receiver will turn off the appliance. A single "beep"
from the Receiver confirms reception of the command.
Figure 13
920-019
Figure 6: Remote Control
display
Figure 5: Remote Control dis-
play in Celsius.
Figure 12
Figure 6: Remote Control
display
Figure 14
Fig. 8
Room Thermostat (Transmitter Operation)
Remote dimmer control (Light)**
Remote‑Flame Control
The Remote Control can operate as a room thermostat. The thermostat
The auxiliary function controls the AUX power outlet by the dimmable
The Proflame has six (6) flame levels. With the system on, and the flame
light control. To activate this function use the Mode Key (fig. 1) to index
can be set to a desired temperature to control the comfort level in a room.
level at the maximum in the appliance, pressing the Down Arrow Key
to the AUX icon (fig. 15 & 16).
To activate this function, press the Thermostat Key (Fig. 1). The Lcd
once will reduce the flame height by one step until the flame is turned off.
The intensity of the output can be adjusted through six (6) levels. Use
display on the Transmitter will change to show that the room thermostat
The Up Arrow Key will increase the flame height each time it is pressed.
the Up/Down Arrow Keys (fig.1) adjust the output level (fig. 16). A single
is "ON" and the set temperature is now displayed (Fig. 9). To adjust the
If the Up Arrow Key is pressed while the system is on but the flame is off,
"beep" will confirm reception of the command.
set temperature, press the Up or Down Arrow Keys until the desired set
the flame will come on in the high position. ( Fig. 7 & 8 ) A single "beep"
temperature is displayed on the LCD screen of the Transmitter.
will confirm reception of the command.
Note: This function is available only with the IFC Control Module.
Fig. 7
Figure 9
Figure 15
KEY LOCK
Fig. 8
This function will lock the keys to avoid unsupervised operation.
To activate this function, press the MODE and UP Keys at the same
2
18
time (fig. 21).
To de-activate this function, press the MODE and UP Keys at the same
time.
Room Thermostat (Transmitter Operation)
The Remote Control can operate as a room thermostat. The thermostat
can be set to a desired temperature to control the comfort level in a room.
To activate this function, press the Thermostat Key (Fig. 1). The Lcd
display on the Transmitter will change to show that the room thermostat
is "ON" and the set temperature is now displayed (Fig. 9). To adjust the
set temperature, press the Up or Down Arrow Keys until the desired set
temperature is displayed on the LCD screen of the Transmitter.