Output Terminal Function Selection (Pr. 64, Pr. 505) - Mitsubishi Electric FR-C500 Instruction Manual

Transistorized inverter
Table of Contents

Advertisement

3.5.2

Output terminal function selection (Pr. 64, Pr. 505)

You can change the functions of the open collector and contact output terminals.
Param
eter
64
RUN terminal function selection
506
ALM terminal function selection
<Setting>
Signal
Setting
Name
0
RUN
Inverter running
3
OL
Overload alarm Output while stall prevention function is activated.
99
ALM
Alarm output
9998
No function
REMARKS
The same function may be set to more than one terminal.
Name
Function
Output during operation when the inverter output
frequency rises to or above the starting frequency.
Output when the inverter's protective function is
activated to stop the output (major fault).
No function (Can be used as a general-purpose
input terminal using the PLC function.)