3.6.3

Reset selection/PU stop selection (Pr. 75)

You can make reset input acceptance selection and choose the stop function
from the operation panel (PU).
! Reset selection
! PU stop selection : When an alarm, etc. occurs in any operation mode, you
Parameter
Name
Reset selection/
75
PU stop selection
<Setting>
Pr. 75
Reset Selection
Setting
0
Reset input normally enabled.
Enabled only when the protective
1
function is activated.
14
Reset input normally enabled.
Enabled only when the protective
15
function is activated.
(1) How to make a restart after a stop by the
operation panel (Restarting method with
1) After completion of
deceleration to a stop,
switch off the STF or STR
signal.
PU
2) Press the
key to show
EXT
PU
...... (
canceled)
PU
3) Press the
key to
EXT
EXT
return to
.
4) Switch on the STF or STR
signal.
REMARKS
•By entering the reset signal (RES) during operation, the inverter shuts off its output while it is
reset, the internal thermal summation value of the electronic overcurrent protection and the
number of retries are reset, and the motor coasts.
•The Pr. 75 value can be set any time. Also, if parameter clear is executed, this setting will not
return to the initial value.
•When the inverter is stopped by the PU stop function, the display alternates between
. An alarm is not output.
: You can choose the reset function input (RES signal)
timing.
can make a stop from the operation panel by pressing the
STOP
key.
RESET
Factory Setting
14
The PU stop key is invalid.
Note that the
operation mode.
Pressing the
to a stop in any of the PU, external, communication
and PLC function operation modes.
Speed
Operation
panel
STF
ON
(STR) OFF
Stop and restart example for external operation
71
Operation Selection Function Parameters
Setting Range
0, 1, 14, 15
PU Stop Selection
STOP
key is valid in the PU
RESET
STOP
key decelerates the inverter
RESET
STOP
key input from the
RESET
shown)
PU
key
EXT
STOP
key
RESET
Time