Function (Parameter) List
Func
Para-
meter
tion
Parameter write
77*
disable selection
Operation mode
79
selection
PU display
145
language
selection
RS-485
communication
331
station number
setting
RS-485
332
communication speed
333 Stop bit length
Parity check
334
presence/absence
Number of
335
communication retries
Communication check
336
time interval
337 Waiting time setting
indicates the communication parameters. Note them when clearing the parameters.
(Refer to pages 89, 125.)
Name
Setting Range
0: Write enabled only
during stop
1: Write disabled
(except some)
2: Write enabled
during operation
0: PU/external
switchable
1: PU 2: External
3: External/PU
combined
4: External/PU
combined
0: Japanese
1: English
2: German
3: French
4: Spanish
5: Italian
6: Swedish
7: Finish
0 to 31: Specify the
48:4800bps,
96:9600bps
192:19200bps
0: Data length 8,
stop bit 1
1: Data length 8,
stop bit 2
10: Data length 7,
stop bit 1
11: Data length 7,
stop bit 2
0: Absence
1: With odd parity
check
2: With even parity
check
0 to 10, 9999
0 to 999s, 9999
0 to 150ms, 9999
Minimum
Setting
Increme
nts
1
1
1
station
1
number of the
inverter.
1
1
1
1
0.1s
1
52
Refer
Custo
Factory
ence
mer
Setting
Page
Setting
0
74
0
75
0
93
0
79
96
79
0
79
1
79
1
79
9999
79
9999
79

Advertisement