Writing The Inverter Parameters - Mitsubishi Electric FR-C500 Instruction Manual

Transistorized inverter
Table of Contents

Advertisement

Inverter Parameter Read/Write Method
4.8.2

Writing the inverter parameters

When data are stored into the corresponding registers of the inverter parameters
(refer to page 110) and the parameter write command is turned from off to on, the data
are written to the parameters that are the targets of all device data. (After that, the
write completion is turned on.)
As soon as the inverter parameter write completion (X29 (RAM) or X2B (E
turns on, 0 is set to D9150 on normal completion.
If an error occurs during access to the parameters, e.g. if any value outside the setting
range is written or write is performed during inverter operation, the value of parameter
No. + H8000 is set to D9150 as soon as the write completion signal (X29 (RAM) or
2
X2B (E
PROM)) turns on, resulting in abnormal completion. If abnormal completion
occurs, the parameters are not written. (For example, if an error occurs in the torque
boost, H8000 is written to D9150.)
For whether inverter parameter write can be performed or not, refer to Pr. 77
"parameter write disable selection" (page 74).
Command
Parameter write command (RAM)
Parameter write completion (RAM)
Parameter write command (E
Parameter write completion (E
POINT
Inverter parameter write must be performed in the PU operation mode and CC-
Link operation mode. (Refer to page 75.)
Device No.
Y29
X29
2
Y2B
PROM)
2
X2B
PROM)
132
2
PROM))