Chapter 6
Cabling the Line Ports and Completing the Installation
Step 2
Connect both SCE 2000 platforms to the management station. (See
Interface
Step 3
Connect the cascade ports. (See
Set topology configurations for each SCE 2000 platform via the connection-mode options. (See
Step 4
Topology-Related Parameters for Redundant Topologies
Make sure that the SCE 2000 platforms have synchronized and active SCE 2000 platform was
Step 5
selected.
Use the show interface linecard 0 connection-mode command.
If you want to start with bypass/sniffing, change the link mode to your required mode in both
Step 6
SCE 2000 platforms on both links. The bypass mode will be applied only to the active SCE 2000
platform. (See
Step 7
Make sure that the link mode is as you required. (See
Use the show interface linecard 0 link mode command.
Step 8
Connect the traffic port of SCE 2000 platform #1. This will cause a momentary down time until
the network elements from both sides of the SCE 2000 platform auto-negotiate with it and start
working (when working inline). (See
Connect the traffic port of SCE 2000 platform #2, this will cause a momentary down time until
Step 9
the network elements from both sides of the SCE 2000 platform auto-negotiate with it and start
working (when working inline). (See
When full control is needed, change the link mode on both SCE 2000 platforms on both links to
Step 10
'forwarding'. It is recommended to first configure the active SCE 2000 platform and then the
standby. (See
Step 11
You can now start working with the Subscriber Manager.

CLI Commands

This section presents CLI commands relevant to the configuration and monitoring of a redundant
system.
Use the following commands to configure and monitor a redundant system:
Topology-Related Parameters for Redundant Topologies
All four of the topology-related parameters are required when configuring a redundant topology.
OL-7824-04
(on page 5-25).)
Link Mode
(on page 6-13).)
Link Mode
(on page 6-13).)
connection-mode
[no] force failure-condition
Show interface linecard 'number' connection-mode
Show interface linecard 'number' physically-connected links
Connection mode — Redundancy is achieved by cascading two SCE 2000 platforms.
Therefore the connection mode for both SCE 2000 platforms may be either:
Inline-cascade
Dual Link: Two
SCE
2000s Topology
(on page 6-11).)
Monitoring the System
Dual Link: Two
SCE
Dual Link: Two
SCE
Cisco SCE 2000 4xGBE Installation and Configuration Guide
Installing a Cascaded System
Connecting the Management
(on page 6-5).)
(on page 6-14).)
2000s Topology
(on page 6-5).)
2000s Topology
(on page 6-5).)