Endless Pools FASTLANE PRO Owner's Manual page 13

Hide thumbs Also See for FASTLANE PRO:
Table of Contents

Advertisement

The threaded rods must be tied into the pools bonding grid. Secure a bonding clamp to each threaded rod. Attach a #8
solid copper wire to each bonding clamp. These wires MUST be attached to a bonding connection that's incorporated into
the pools bonding grid. In most cases this will be a connection at the rebar. Verify ALL bonding connections are tight before
shooting gunite (Fig 4.4).
Fig. 4.4
Prior to shooting gunite, it is critical that the opening of each thru-wall and the threaded rods that extend
into the finished pool be covered. No gunite can be embedded in these areas.
After verifying the bracket is positioned, bonding connections are secure, and thru-wall openings/threaded
rods are covered, gunite can be shot (Fig 4.5).
Fig. 4.5
.
Fastlane
Pro Swim Unit Installation
®
12

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FASTLANE PRO and is the answer not in the manual?

Questions and answers

Table of Contents