Undetermined Problems - Cisco Wide Area Virtualization Engine 274 Hardware Installation Manual

Wide area virtualization engine
Table of Contents

Advertisement

Undetermined Problems

Table 5-1
Ethernet Troubleshooting Chart (continued)
Ethernet Controller
Problem
Data is incorrect or
sporadic.
The Ethernet
controller stopped
working without
apparent cause.

Undetermined Problems

Note
Note
Step 1
Step 2
Step 3
Cisco Wide Area Virtualization Engine 274 and 474 Hardware Installation Guide
5-6
Actions
Check the following:
Make sure that you are using Category 5 or higher cabling when operating
the device at 100 Mbps or 1000 Mbps.
Make sure that the cables do not run close to noise-inducing sources such
as fluorescent lights.
Check the following:
Try a different connector on the switch.
Reseat or replace the adapter.
Use the information in this section if the diagnostic tests did not identify the
failure, the devices list is incorrect, or the system is inoperative.
Damaged data in CMOS can cause undetermined problems.
Damaged data in the BIOS code can cause undetermined problems.
Check the front panel Power LED. If the LED indicates the power supply is
working correctly, follow these steps:
Power down the device.
Make sure that the device is cabled correctly.
Remove or disconnect the following devices (one at a time) until you find the
failure (power up the device and reconfigure it each time):
Any non-Cisco devices
Surge suppressor device (on the device)
Chapter 5
Troubleshooting the System Hardware
OL-17739-01