Festo CPX-CMIX-M1-1 Brief Description page 12

Cpx-terminal. measuring module
Hide thumbs Also See for CPX-CMIX-M1-1:

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 9
Removing:
S
Remove the screws and lift the CMIX up carefully.
Mounting:
1. Check the seal and sealing surfaces and refit the
connection block.
2. Screws must be fitted so that the self-cutting threads
can be used. Tighten the screws by hand in diagonally
opposite sequence. Tightening torque 0.9 ... 1.1 Nm.
3.3 Pin assignment of axis connection
X
12
Pin
Assignment
1
+24 V logic voltage
2
+24 V load voltage
3
0 V
4
CAN_H
5
CAN_L
Housing
Cable shield
Festo CPX−CMIX−Z6 1112NH English