Removing And Replacing The System Board Cooling Fans - HP Visualize B1000 Supplementary Manual

Visualize b class and c class unix workstations
Hide thumbs Also See for Visualize B1000:
Table of Contents

Advertisement

Parts Removal and Replacement

Removing and Replacing the System Board Cooling Fans

Removing and Replacing the System Board Cooling Fans
This section describes how to remove and replace the System Board Cooling Fans.
NOTE
Prior to removing the System Board Cooling Fans, the Left Side Panel, Power
Supply, and Air Divider need to be removed. See the appropriate section(s) for
the steps on removing and replacing these components.
Figure 2-37.
Top Fan Rivets
Lower Fan
Rivets
NOTE
When the fan failed, it was identified on the front panel display. Fan #2 refers
to the lower fan and Fan #3 refers to the top fan.
1. Locate the fan that failed.
2. While holding the faulty fan, pull out the plastic rivets from the back of the
workstation. Snug rivets may need to be pried out with a tool. For the top fan, pull it
toward the front of the workstation to remove it. For the lower fan, slide it toward the
bottom of the workstation and lift it out.
44
Top Fan Rivets
Fan #3
Fan #2
Lower Fan
Rivets
Chapter 2