5.9.3 Clear History

Parameter
O03.01
Elapsed Time Setting
O03.02
Elapsed Time Selection
00 Power On Time
01 Running Time
O03.03
Fan ON Time Set
O03.05
Capacitor Maintenance
Setting
O03.07
Pre-Charge Relay
Maintenance Setting
O03.09
IGBT Maintenance Setting
O03.11
Fault Trace Clear
00 Not Cleared
01 Clear U2/U3
O03.12
kWh Monitor Initial Value
Selection
00 No Reset
01 Reset
O03.14
Clear Count History
00 Not Clear
01 Reset Runs
02 Clear OL/LC Count
03 Clear Both Counts
Name
Accumulated operation time displayed in
monitor U04.01.
Selects how the Elapsed Time is accumulated
Sets the value of the Fan Operation Time
monitor (U04.03) in units of 10 hours. A setting
of 30 = 300 hours
DC Bus Capacitors maintenance time displayed
in U04.05 as a percentage of the total expected
performance life.
Pre-Charge Relay maintenance time displayed
in U04.06 as a percentage of the total expected
performance life.
IGBT maintenance time displayed in U04.07 as
a percentage of the total expected performance
life.
Clears Fault History
Sets kWh Monitor Initial Value
Clears count history
Function
IMPULSE
Range
Default
0000–9999hr
0000
00, 01
01
0000–9999 x
0000
10hr
000–150%
000
000–150%
000
000–150%
000
00, 01
00
00, 01
00
00–03
00
®
•G+ Mini Technical Manual
November 2020
Page 127