Magnetek IMPULSE G+ Mini Technical Manual page 70

Hide thumbs Also See for IMPULSE G+ Mini:
Table of Contents

Advertisement

Parameter
C05.01
Load Check (LC)
00 Disable
01 Enable Load Check
03 Enable Load Check Continuous
09 Load Check Set Up
C05.02
LC Alarm Action
00 Alarm Only (Continue operation)
01 Decel to Stop (Allows lower only)
02 Coast to Stop (Allows lower only)
03 Fault Stop (No operation)
04 Use B03.03 Method (allows lower only)
05 B03.03 with Reset (allows lower only)
C05.03
LC Setting Time
C05.04
LC Testing Time
C05.05
LC Acceleration Margin
C05.07
LC Margin
C05.08
LC Lowering Speed
C05.09
LC Zone 01
C05.10
LC Zone 02
C05.11
LC Zone 03
C05.12
LC Zone 04
C05.13
LC Zone 05
C05.14
LC Zone 06
C05.15
LC Zone 07
C05.16
LC Zone 08
C05.17
LC Zone 09
C05.18
LC Zone 10
C05.19
LC Zone 11
C05.20
LC Zone 12
C05.21
LC Zone 13
Name
Used to set up and enable the Load
Check function.
Sets the action at a Load Check alarm
or fault (Fault reset is required via
keypad or MFDI to raise the load).
Sets the time to hold the output
frequency allowing the output current/
torque to stabilize.
Sets the time (after the LC Setting Time)
for comparing output current/torque to
values for a particular LC Zone being
tested.
Sets the margin for Load Check
detection during acceleration. A setting
of 00 is the most sensitive.
Sets the margin for Load Check
detection at speed agree. A setting of 00
is the most sensitive.
Sets the maximum lowering speed after
an LC alarm.
Current/Torque for Zone 01
Current/Torque for Zone 02
Current/Torque for Zone 03
Current/Torque for Zone 04
Current/Torque for Zone 05
Current/Torque for Zone 06
Current/Torque for Zone 07
Current/Torque for Zone 08
Current/Torque for Zone 09
Current/Torque for Zone 10
Current/Torque for Zone 11
Current/Torque for Zone 12
Current/Torque for Zone 13
Function
0.00–2.55 sec
0.00–2.55 sec
®
IMPULSE
Range
Default
00, 01, 03, 09
00
00–05
04
0.15
0.25
00–50
5
00–20
5
0.1–30.0 Hz
6.0
000–250%
000
000–250%
000
000–250%
000
000–250%
000
000–250%
000
000–250%
000
000–250%
000
000–250%
000
000–250%
000
000–250%
000
000–250%
000
000–250%
000
000–250%
000
•G+ Mini Technical Manual