Magnetek IMPULSE G+ Mini Technical Manual page 89

Hide thumbs Also See for IMPULSE G+ Mini:
Table of Contents

Advertisement

Parameter
E02.01
Motor Rated FLA
E02.02
Motor Rated Slip
E02.03
No-Load Current
E02.04
Number of Poles
E02.05
Terminal Resistance
E02.06
Leakage Inductance
E02.07
Saturation Comp 1
E02.08
Saturation Comp 2
E02.09
Motor Mechanical Loss
E02.10
Motor Iron Loss of Torque
Compensation
E02.11
Motor Rated Power
E02.12
Saturation Comp 3
* Initial value is determined by O02.04 (kVA Selection)
** This value is automatically set during auto tuning
Name
Motor-rated current full load amps
Motor-rated slip frequency
Motor no-load current
Number of poles in motor
Motor terminal resistance
Motor Leakage Inductance
Core-Saturation Compensation
Coefficient 1
Core-Saturation Compensation
Coefficient 2
Mechanical Torque Loss as a % of
motor torque
Motor iron loss
Motor rated power output
Core-Saturation Compensation
Coefficient 3
Function
IMPULSE
Range
Default
0.01–70.0 A
*
0.00–20.00 Hz
**
0.0–70.0 A
**
02–48
04
0.000–65.000 Ω
**
0.0–40.0%
**
0.00–0.50
**
0.00–0.75
**
0.0–10.0%
0.0
0–65535 W
**
0.0–20.0 HP/kW
**
1.30–5.00%
**
®