I/O Signals Transferred To/From The Master Module - Mitsubishi Electric AJ65BT-D62 User Manual

High-speed counter module
Hide thumbs Also See for AJ65BT-D62:
Table of Contents

Advertisement

3. SPECIFICATIONS

3.5 I/O Signals Transferred to/from the Master Module

Input Signals
CH1
RXn0
RXn1
RXn2
RXn3
RXn8
RXn9
RXnA
RXnE
RX(n+1)0
RX(n+1)2
RX(n+1)1
RX(n+1)3
RX(n+1)4 to RX(n+7)7
RX(n+7)8
RX(n+7)9 to RX(n+7)A
RX(n+7)B
RX(n+7)C to RX(n+7)F
Downloaded from
ManualsNet.com
This section explains the input/output signals (RX, RY) of the high-speed counter
module transferred to/from the master module.
(1) Input signals
The following table lists the input signals of the high-speed counter module
transmitted to the master module.
Signal Name
High-speed counter module
CH2
master module
Counter value greater
RXn4
(point No. 1)
Counter value coincidence
RXn5
(point No. 1)
RXn6
Counter value less (point No. 1)
External preset
RXn7
command detection
Counter value greater
RXnB
(point No. 2)
Counter value coincidence
RXnC
(point No. 2)
RXnD
Counter value less (point No. 2)
RXnF
———
Preset completion
Counter function detection
———
Initial data processing request flag
———
Remote ready
———
POINT
The unusable devices are used in the system and should not be used by the
user.
If any of them is used by the user, normal operation cannot be guaranteed.
search engine
Description
Turned on if the counter value is greater than the set
value No. 1.
Latched on if the counter value is equal to the set value
No. 1 turned off by the coincidence signal reset
command.
Turned on when the counter value is less than the set
value No. 1.
Latched on when the preset request is given from
external input. Turned off by the external preset
detection reset command.
Turned on if the counter value is greater than the set
value No. 2.
Latched on if the counter value is equal to the set value
No. 2 turned off by the coincidence signal reset
command.
Turned on when the counter value is less than the set
value No. 2.
Unusable
Turned on on completion of the preset function
executed when the preset command
{(RY(n+1)1(RY(n+1)8)} turns on.
Turned off when the preset command switches from ON
to OFF.
Turned on at counter function start (execution) when the
counter function selection start command
{(RY(n+1)6(RY(n+1)D)} turns on.
Turned off when the counter function selection start
command switches from ON to OFF.
Unusable
Turned on by the high-speed counter module to request
initial data setting after power-on or hardware reset.
Turned off on initial data processing completion (when
initial data processing completion flag (RY(N+7)8) turns
on).
Unusable
Turned on when the high-speed counter module is in
the ready state on completion of initial data setting after
power-on or hardware reset.
Unusable
n: Address assigned to the master station by station number setting.
3 - 12
MELSEC-A
Refer To
Section 6.1
Section 6.1
Section 8.1
Section 6.1
Section 7.3
Section 6.1
———
Section 7.2
Section 9.2
Section 9.3
Section 9.4
Section 9.5
———

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aj65bt-d62dAj65bt-d62d-s1