Can only be used if
Primary reporting format
is Ademco Contact ID.
If reporting to Pager,
choose from 6, 7, 8, or 9,
as desired.
www.PDF-Zoo.com
Press
45 PHONE SYSTEM SELECT
If Central Station Receiver is not on WATS line:
0 = Pulse Dial, 1 = Tone Dial.
If Central Station Receiver is on WATS line:
2 = Pulse Dial, 3 = Tone Dial.
Press 46
REPORT FORMAT, PRIMARY/SECONDARY
Determines which format is to be used to report to the central
station.
0 = 3+1; 4+1 ADEMCO Lo Speed Standard (this is the default)
1 = 3+1; 4+1 Radionics Standard
2 = 4+2 ADEMCO Lo Speed Standard
3 = 4+2 Radionics Standard
6 = 4+2 ADEMCO Express
7 = ADEMCO Contact ID Reporting
8 = 3+1; 4+1 ADEMCO Lo Speed Expanded
9 = 3+1; 4+1 Radionics Expanded
(Enter
as the 4th digit of
used.)
Note:
The maximum number of alarm and alarm restore reports
during one armed period is determined by field 92.
Press
47 SPLIT/DUAL REPORTING
Enter 0 to disable (Backup report only). This is the default.
TO PRIMARY PHONE No.
1 =
Alarms, Restore, Cancel
2 =
All except Open/Close, Test
3 =
Alarms, Restore, Cancel
4 =
All except Open/Close, Test
5 =
All reports
TO PRIMARY PHONE #
6 =
All reports except Open/Close
7 =
All reports
8 =
All reports
9 =
All reports except Open/Close
‡ Will report only Users 5–8. If using wireless button-type devices, the zone
number of the arm or disarm button (10–25) will be sent as the user number.
Entries 6 through 9 will send a report to a pager (in addition to the selected
primary phone number), but you must enter the pager number as the
secondary phone number in field 42.
A 10-digit code is sent to the pager which will take the following format:
4-digit Subscriber No.
(as entered in field
43)
3-Digit Event Code, as follows:
911 = Alarm (NNN = Zone No.)
001 = Open, System disarmed (NNN = User No.)
002 = Close, System armed ( NNN = User No.)
811 = Trouble ( NNN = Zone No.)
† The first digit of the Subscriber No. entered in field
USE "0"); the last 3 digits can be 0–9. Failure to observe this requirement may
interfere with paging services.
– 67 –
firealarmresources.com
Enter 1 digit (default = 0)
43 if 3+1 dialer reporting is to be
TO SECONDARY PHONE No.
Other Reports
Open/Close, Test
All reports
All reports
All reports
TO PAGING NUMBER
Alarms, Open/Close, Troubles
Alarms, Troubles
Alarms, Open/Close, Troubles
Alarms, Open/Close for User
Nos. 5–25
‡, Troubles
SSSS –EEE–NNN
3-digit User or Zone No.
43 must be 1–9 (DO NOT
*
(continued)