Output Relay Displays
Enter Relay No.
(00 = Quit)
02
A EV ZL ZT
STT 0
0
02
A EV ZL ZT
STP –
02 Relay Action
No Response
02 Start Event
Not Used
02 Start:
No List
02 Start:
Not Used
02 Stop:
No List
02 Stop:
Not Used
02
A EV ZL ZT
STT 0
0
02
A EV ZL ZT
STP – –
www.PDF-Zoo.com
Upon pressing 80, this screen will appear. Enter the Relay Number 01, 02,
03, or 04 for a 4204 (or 00 to end these entries). Press the [ ] key to
01
continue.
The [ ] key is used to accept an entry and advance to the next prompt. The
[#] key is used to revert back to the last question to check or change an
entry. Press [ ] to go forward again.
This screen displays a summary of the current Relay START programming
(for this example, relay 02 has been selected).
0 00
Press the [ ] key to continue.
This screen displays a summary of the current Relay STOP programming.
Press the [ ] key to continue.
0
00
Enter the desired relay action as listed below. Press the [ ] key to continue.
0 = No response
0
1 = Close for 2 seconds
Enter the event to START the relay:
0 = Not used; 2 = Fault; 1 = Alarm; 3 = Trouble
0
A zone list must be used in conjunction with an event. If a zone type/system
operation is to be used instead of an event, enter 0.
Press the [ ] key to continue.
If a zone list will be used to START the relay action, enter the zone list number
Zn List
(to be programmed in field 81): 1, 2, or 3. If not used, enter 0. Press the [ ]
0
key to continue.
If a zone type or system operation will be used to START the relay action,
Zn Typ
enter the appropriate two-digit code (see table that follows). If not, enter 00.
00
Press the [ ] key to continue.
00 = Not Used
01 = Entry/Exit
03 = Perimeter
04 = Interior Follower
20 = Arming–Stay
21 = Arming–Away
22 = Disarming (Code + OFF) 35 = Code + # + 8 Key Entry
31 = End of Exit Time
32 = Start of Entry Time
If a zone list will be used to STOP, or restore, the relay action, enter the zone list
Zn List
(ZL) number 1, 2, or 3 (to be programmed in 81 mode). If not used, enter 0.
0
Press the [ ] key to continue.
If a zone type or system operation will be used to STOP the relay action, enter
Zn Typ
the appropriate two digit code (see the "ZT" choices listed above). If not, enter
00
00. Press the [ ] key to continue.
This screen again displays a summary of the current relay START
programming.
0
00
Press the [ ] key to continue.
This screen again displays a summary of the current relay STOP programming.
Press the [ ] key to continue.
0
00
firealarmresources.com
2 = Close and Stay Closed
3 = Continuous Pulse on & off
CHOICES FOR ZONE TYPES
05 = Trouble Day/Alarm Night 08 = 24 Hr Aux
06 = 24 Hr Silent
07 = 24 Hr Audible
CHOICES FOR SYSTEM OPERATION
33 = Any Burglary Alarm
34 = Code + # + 7 Key Entry
36 = At Bell Timeout**
38 = Chime
**Or at Disarming, whichever occurs earlier.
– 42 –
( 1 sec ON, 1 sec OFF)
09 = Fire
10 = Interior w/Delay
39 = Any Fire Alarm
40 = Bypassing
41 = AC Power Failure
42 = System Batt. Low
58 = Duress