Menu Items - Kane KANE958 Manual

Flue gas analyser with direct o2 measurement and co sensor protection
Table of Contents

Advertisement

MENU ITEMS

MENU ITEM MENU TEXT
TIME
DATE
HEADER
PRINTER TYPE
GAS SCALE
O2 REF
IF NO OPTION
FITTED
LOGS
AIRFLOW
EFF
LANGUAGE
UTIL
CODE
16 KANE958 MANUAL
TIME
DATE
HEADER
IR PRINT
GAS UNIT
O2 REF
Enables selection of NOx equation types
and assumed percentage of NO2.
NOX CALC
NOx equations are:
NOx reference to NO
NOx sum equation (NO + NO2)
NOx reference to NO2
LOGS
AIRFLOW
Change airflow scale and adjust pitot factor
EFF
LANGUAGE
Consists of a sub menu to:
INFO - View firmware information
UTIL
B'LIGHT - Set backlight timeout (S)
LEAK - Perform system integrity test
Password protected for authorised service
CODE
OPTIONS/COMMENTS
HH:MM:SS format
E.G.. 7am = 07:00:00, 7pm = 19:00:00
DD/MM/YY format
Edit 2 Line Header on your printouts
Select, KMIRP, IRP-3
Select, ppm, mg/m3, Mg/kWh
Used for "Normalised" readings.
Default set to 3%, can be adjusted up or
down
View current memory usage & stored
logs
Efficiency calculation analyser set to
Gross or Net -
Condensing automatically selected
based on selected fuel type
Select required language from list
agents only - Default to 000000