+5VSB Fall Time - RECOMMENDATION

Power supply 5VSB is recommended to go down to low level within 2 seconds under
any load condition after AC power is removed as shown in
will test at Light 20% Load. If system requires specific +5VSB fall time, the PSU
design is recommended to support it.

Figure 4-7: 5VSB Fall Time

4.5

Output Protection

4.5.1
Over Voltage Protection (OVP) – REQUIRED
The over voltage sense circuitry and reference shall reside in packages that are
separate and distinct from the regulator control circuitry and reference. No single
point fault shall be able to cause a sustained over voltage condition on any or all
outputs. The supply shall provide latch-mode over voltage protection as defined in
Table
4-12.

Table 4-12: Over Voltage Protection

(or 12V1DC and 12V2DC)
NOTE: Over voltage protection is RECOMMENDED but not REQUIRED for this output. While over
42
Output
+12 VDC
+5VDC
+3.3VDC
+5VSB
1
voltage protection is not required for this output, system damage may occur in the case
of an over voltage event.
Minimum (V)
Nominal (V)
13.4
5.74
3.76
5.74
Figure
4-7. Intel
®
Maximum (V)
15.0
15.6
6.3
7.0
4.2
4.3
6.3
7.0