Intel core 2 extreme quad-core mobile processor, intel core2 quad mobile processor, intel core 2 extreme mobile processor, intel core 2 duo mobile processor, intel core 2 solo mobile processor and intel celeron processor on 45-nm process specification upd (56 pages)
Summary of Contents for Intel AXXRMS2LL040
Page 1
® Intel RAID Module RMS2LL040(AXXRMS2LL040) and RMS2LL080(AXXRMS2LL080) Hardware User’s Guide Intel Order Number: E97251-002...
Page 2
Intel may make changes to specifications and product descriptions at any time, without notice. Intel is a trademark or registered trademark of Intel Corporation or its subsidiaries in the United States and other countries. *Other names and brands may be claimed as the property of others.
RMS2LL080. • Chapter 2 describes the procedures for installing and configuring the RAID module. ® • Chapter 3 provides the characteristics and technical specifications for the Intel RAID Module RMS2LL040 and RMS2LL080. • Appendix A explains drive roaming. •...
RAID Module RMS2LL040 and RMS2LL080 offer a cost-effective way to implement RAID in a server for internal storage. ® As the second generation PCI Express* storage adapters, the Intel RAID Module RMS2LL040 and RMS2LL080 address the growing demand for increased data throughput and scalability requirements across mid to low-end servers and workstations.
Note: Additional Intel Server Boards and Systems may be supported. For the most up-to-date ® list, see the Compatibility section under the link for this Intel RAID Module at http://www.intel.com/support/go/motherboards/server/index.htm. The SAS RAID controllers support the SAS protocol as described in the Serial Attached SCSI Standard, Version 2.0.
Failures are logged in Intel RAID Web Console 2, CIM, and LEDs. SAS/SATA Features of the LSI* LSISAS2008 Processor Chip “LSI* LSISAS2008 Processor Chip” for SAS/SATA features of the LSI* LSISAS2008 Processor Chip. Intel® RAID Module RMS2LL040 and RMS2LL080 Hardware User’s Guide...
“Installing the RAID Module”) Note: Intel Corporation strongly recommends using an uninterruptible power supply (UPS). Installing the RAID Module To install the RAID Module, follow these steps: 1. Turn off the power to the system, all drives, enclosures, and system components.
The cable length should be reduced by about one foot (.33 meters) if using a backplane. You may connect one device per SATA/SAS cable either as a device or as an expander. Intel® RAID Module RMS2LL040 and RMS2LL080 Hardware User’s Guide...
Use only “straight” SAS cables, not “cross-over” SAS cables. . AF003488 Figure 3. Connecting Cable between the RAID Module and Drives/Backplane 7. Install the server system cover and connect the power cords. See your server system documentation for instructions. Intel® RAID Module RMS2LL040 and RMS2LL080 Hardware User’s Guide...
Page 18
® After performing the Intel RAID Module RMS2LL0x0 installation, you must configure ® the storage adapter and install the operating system driver. The Intel RAID Software User’s Guide (Document Number: D29305-0xx) provides configuration options and ® instructions for the Intel RAID Module RMS2LL0x0, as well as detailed installation instructions for operating system drivers.
Supports single PHY or wide ports consisting of 2, 3, or 4 PHYs within a single quad port. • Allows addressing of multiple SATA targets through an expander if using SATA 2.0- compliant hard disk drives. Intel® RAID Module RMS2LL040 and RMS2LL080 Hardware User’s Guide...
Allows multiple initiators to address a single target (in a fail-over configuration) through an expander. For more information, see http://www.lsi.com/. ® Note: Some of these chip features may not be supported by Intel Integrated RAID Module RMS2LL040 and RMS2LL080. Flash ROM An 4-MB CFI-compliant flash ROM is used to accommodate RAID firmware and RAID BIOS Console 2 OpROM.
Transmit pins connect to receive pins on the other device. The SAS/SATA connector is keyed at pin 1. These pin-outs for the serial ATA connector are not compatible with the legacy PATA connector. Figure 8. SAS/SATA Interface Intel® RAID Module RMS2LL040 and RMS2LL080 Hardware User’s Guide...
PCI Express* lanes signaling as defined in the PCI Express Specification 2.0. This interface also provides +3.3 V power to the board. Figure 10. PCI Interface Intel® RAID Module RMS2LL040 and RMS2LL080 Hardware User’s Guide...
Upto 5.0 Gigabit/sec per PCI Express* lane Drive data transfer rate Upto 6 Gigabit/sec per lane Maximum queue tags per As many as the drive can accept drive Strip size 64 KB Cache Options Disk cache enabled/disabled Intel® RAID Module RMS2LL040 and RMS2LL080 Hardware User’s Guide...
The storage and transit environment conditions are: • Temperature range from -30°C to 80°C (dry bulb) • Relative humidity range: 5% to 90% non-condensing • MTBF (electrical components) number: 298,900 hours at 40°C Intel® RAID Module RMS2LL040 and RMS2LL080 Hardware User’s Guide...
The Intel RAID Module RMS2LL040 and RMS2LL080 supports LSI* expanders and Maxim SAS expanders, that are used as a component in Intel enclosures. Other expanders may be supported post launch, based on market conditions and customer requirements. Support for Non-Hard Disk Drive Devices As SAS-based non-hard drive devices were not available when this controller was in development, support for these devices will be determined as they become available.
The fundamental purpose of a RAID system is to present a usable data storage medium (virtual drive) with some level of redundancy to a host operating system. The Intel® RAID firmware is based on the concept of associating physical drives in arrays and then creating a virtual drive from that array that includes a functional RAID level.
6. Install the server cover. For instructions, see your server system documentation. 7. Plug in and power on the system. The controller detects the RAID configuration from the configuration data on the drives (COD). Intel® RAID Module RMS2LL040 and RMS2LL080 Hardware User’s Guide...
When working inside your computer: • Do not attempt to service the computer system yourself, except as explained in this guide and elsewhere in Intel documentation. Always follow installation and service instructions closely. • Turn off your computer and any peripherals.
Page 36
When transporting a sensitive component, first place it in an antistatic container or packaging. • Handle all sensitive components in a static-safe area. If possible, use antistatic floor pads and workbench pads. Intel® RAID Module RMS2LL040 and RMS2LL080 Hardware User’s Guide...
Page 37
4. Insert and lock the padlock to the system to prevent unauthorized access inside the system. 5. Connect all external cables and the AC power cord(s) to the system. Intel® RAID Module RMS2LL040 and RMS2LL080 Hardware User’s Guide...
5. Tragen Sie ein geerdetes Antistatik Gelenkband, um elektrostatische Ladungen (ESD) über blanke Metallstellen bei der Handhabung der Komponenten zu vermeiden. 6. Schalten Sie das System niemals ohne ordnungsgemäß montiertes Gehäuse ein. Intel® RAID Module RMS2LL040 and RMS2LL080 Hardware User’s Guide...
Lisez attention toutes les consignes de sécurité et les mises en garde indiquées dans ce ® document avant de suivre toute instruction. Consultez Intel Server Boards and Server Chassis Safety Information sur le CD Resource CD ou bien rendez-vous sur le site http://support.intel.com/support/motherboards/server/sb/cs-010770.htm Intel® RAID Module RMS2LL040 and RMS2LL080 Hardware User’s Guide...
Page 40
4. Remettez le cadenas en place et verrouillez-le afin de prévenir tout accès non autorisé à l'intérieur du système. 5. Rebranchez tous les cordons d'alimentation c. a. et câbles externes au système. Intel® RAID Module RMS2LL040 and RMS2LL080 Hardware User’s Guide...
1. Desbloquee y extraiga el bloqueo de seguridad de la parte posterior del sistema, si se ha instalado uno. 2. Extraiga y guarde todos los tornillos de las tapas.Extraiga las tapas. Intel® RAID Module RMS2LL040 and RMS2LL080 Hardware User’s Guide...
Il cavo è considerato il dispositivo d'interruzione dell'alimentazione principale (in c.a.). La presa alla quale si collega il sistema deve essere installata vicino all'unità e deve essere facilmente accessibile. Intel® RAID Module RMS2LL040 and RMS2LL080 Hardware User’s Guide...
Page 43
Se il sistema è stato a lungo in funzione, il microprocessore e il dissipatore di calore potrebbero essere surriscaldati. Fare attenzione alla presenza di piedini appuntiti e parti taglienti sulle schede e sul telaio. È consigliabile l'uso di guanti di protezione. Intel® RAID Module RMS2LL040 and RMS2LL080 Hardware User’s Guide...
® This Intel RAID Module has been evaluated for regulatory compliance as an Intel end system, and is included as part of the end system certification. For information on end system certification, refer to the product regulatory certification for the end system level product.
Need help?
Do you have a question about the AXXRMS2LL040 and is the answer not in the manual?
Questions and answers