Summary of Contents for Intel AXXRMS2AF080
Page 1
® Intel Integrated RAID Module RMS2AF040(AXXRMS2AF040) and RMS2AF080(AXXRMS2AF080) Hardware User’s Guide Intel Order Number: E93119-002...
Page 2
Intel may make changes to specifications and product descriptions at any time, without notice. Intel is a trademark or registered trademark of Intel Corporation or its subsidiaries in the United States and other countries. *Other names and brands may be claimed as the property of others.
Chapter 2 describes the procedures for installing and configuring the RAID module. ® • Chapter 3 provides the characteristics and technical specifications for the Intel Integrated RAID Module RMS2AF040 and RMS2AF080. • Appendix A explains drive roaming and drive migration.
Fault Tolerance ......................22 Electrical Characteristics .....................23 Thermal and Atmospheric Characteristics ..............23 Safety Characteristics ....................23 Operating Certifications .......................23 Supported Device Technology .....................23 Support for Hard Disk Drive Devices ................24 SAS Expander Support ....................24 Intel® Integrated RAID Module RMS2AF040 and RMS2AF080 Hardware User’s Guide...
Page 6
B. Installation/Assembly Safety Instructions ............29 English ..........................31 Deutsch ..........................32 Français ..........................33 Español ..........................35 Italiano ..........................36 C. Regulatory and Certification Information ............39 Product Safety and EMC Compliance ................. 39 Intel® Integrated RAID Module RMS2AF040 and RMS2AF080 Hardware User’s Guide...
SATA or high performance SAS media. ® As a second generation PCI Express* storage controller, the Intel Integrated RAID Module RMS2AF040 and RMS2AF080 addresses the growing demand for increased data throughput and scalability requirements across entry level, midrange, and enterprise server platforms.
Note: Additional Intel Server Boards and Systems may be supported. For the most up-to-date ® list, see the Compatibility section under the link for this Intel RAID Module at http://www.intel.com/support/go/motherboards/server/index.htm. The SAS RAID controllers support the SAS protocol as described in the Serial Attached SCSI Standard, Version 2.0.
Firmware provides best effort to recognize an error and recover if possible. • Failures are logged from controller and drive firmware, and SMART monitor. • Failures are logged in NVRAM, viewable from OS Event Log, Intel RAID Web ® Console 2; CIM, LEDs.
Migrations supported are RAID 1 to RAID 0, RAID 5 to RAID 0. • With OCE, migrations supported are RAID 0 to RAID 1, RAID 0 to RAID 5, and RAID 1 to RAID 5. Intel® Integrated RAID Module RMS2AF040 and RMS2AF080 Hardware User’s Guide...
“Installing the RAID Module”) Note: Intel Corporation strongly recommends using an uninterruptible power supply (UPS). Installing the RAID Module To install the RAID Module, follow these steps: 1. Turn off the power to the system, all drives, enclosures, and system components.
The cable length should be reduced by about one foot (.33 meters) if using a backplane. You may connect one device per SATA/SAS cable either as a device or as an expander. Intel® Integrated RAID Module RMS2AF040 and RMS2AF080 Hardware User’s Guide...
Use only “straight” SAS cables, not “cross-over” SAS cables. . AF003488 Figure 3. Connecting Cable between the RAID Module and Drives/Backplane 7. Install the server system cover and connect the power cords. See your server system documentation for instructions. Intel® Integrated RAID Module RMS2AF040 and RMS2AF080 Hardware User’s Guide...
After you press the keys to enter the Intel RAID BIOS Console 2 software, the ® firmware takes several seconds to initialize and then display the Intel Integrated RAID module RMS2AF040 or RMS2AF080 number and firmware version. The numbering of the RAID module follows the PCI slot scanning order used by the server board.
Supports single PHY or wide ports consisting of 2, 3, or 4 PHYs within a single quad port. • Allows addressing of multiple SATA targets through an expander if using SATA 2.0- compliant hard disk drives. Intel® Integrated RAID Module RMS2AF040 and RMS2AF080 Hardware User’s Guide...
Allows multiple initiators to address a single target (in a fail-over configuration) through an expander. For more information, see http://www.lsi.com/. ® Note: Some of these chip features may not be supported by Intel Integrated RAID Module RMS2AF040 and RMS2AF080. Flash ROM An 16-MB CFI-compliant flash ROM is used to accommodate RAID firmware and RAID BIOS Console 2 OpROM.
Intel Integrated RAID Module RMS2AF040 and RMS2AF080. These pin-outs for the serial ATA connector are not compatible with the legacy PATA connector. Figure 8. SAS/SATA Interface Intel® Integrated RAID Module RMS2AF040 and RMS2AF080 Hardware User’s Guide...
PCI Express* lanes signaling as defined in the PCI Express Specification 2.0. This interface also provides +3.3 V power to the board. Figure 10. PCI Interface Intel® Integrated RAID Module RMS2AF040 and RMS2AF080 Hardware User’s Guide...
As many as the drive can accept drive Strip size 8, 16, 32, or 64 KB Maximum concurrent 1024 - 16 commands Support for multiple initiators Performance Native command queuing Intel® Integrated RAID Module RMS2AF040 and RMS2AF080 Hardware User’s Guide...
(WHQL) at product launch. Supported Device Technology ® The various device technologies supported by the Intel Integrated RAID Module RMS2AF040 and RMS2AF080 are described in the subsections that follow. Intel® Integrated RAID Module RMS2AF040 and RMS2AF080 Hardware User’s Guide...
The fundamental purpose of a RAID system is to present a usable data storage medium (virtual drive) with some level of redundancy to a host operating system. The Intel® RAID firmware is based on the concept of associating physical drives in arrays and then creating a virtual drive from that array that includes a functional RAID level.
The drive operating condition is not optimal because one of the configured drives has failed or is offline. Offline Offline The drive is not available to the operating system and is unusable. Intel® Integrated RAID Module RMS2AF040 and RMS2AF080 Hardware User’s Guide...
Only drives that comply with the SAS and SATA specification extensions are supported. SAS Bus and ID Mapping Devices on the SAS bus are persistently mapped based on a SAS address. Intel® Integrated RAID Module RMS2AF040 and RMS2AF080 Hardware User’s Guide...
6. Install the server cover. For instructions, see your server system documentation. 7. Plug in and power on the system. The controller detects the RAID configuration from the configuration data on the drives (COD). Intel® Integrated RAID Module RMS2AF040 and RMS2AF080 Hardware User’s Guide...
9. Install the server cover. For instructions, see your server system documentation. 10. Plug in and power on the system. When you start the system, the controller detects the RAID configuration from the configuration data on the drives. Intel® Integrated RAID Module RMS2AF040 and RMS2AF080 Hardware User’s Guide...
When working inside your computer: • Do not attempt to service the computer system yourself, except as explained in this guide and elsewhere in Intel documentation. Always follow installation and service instructions closely. • Turn off your computer and any peripherals.
Page 40
When transporting a sensitive component, first place it in an antistatic container or packaging. • Handle all sensitive components in a static-safe area. If possible, use antistatic floor pads and workbench pads. Intel® Integrated RAID Module RMS2AF040 and RMS2AF080 Hardware User’s Guide...
4. Insert and lock the padlock to the system to prevent unauthorized access inside the system. 5. Connect all external cables and the AC power cord(s) to the system. Intel® Integrated RAID Module RMS2AF040 and RMS2AF080 Hardware User’s Guide...
5. Tragen Sie ein geerdetes Antistatik Gelenkband, um elektrostatische Ladungen (ESD) über blanke Metallstellen bei der Handhabung der Komponenten zu vermeiden. 6. Schalten Sie das System niemals ohne ordnungsgemäß montiertes Gehäuse ein. Intel® Integrated RAID Module RMS2AF040 and RMS2AF080 Hardware User’s Guide...
Lisez attention toutes les consignes de sécurité et les mises en garde indiquées dans ce ® document avant de suivre toute instruction. Consultez Intel Server Boards and Server Chassis Safety Information sur le CD Resource CD ou bien rendez-vous sur le site http://support.intel.com/support/motherboards/server/sb/cs-010770.htm Intel® Integrated RAID Module RMS2AF040 and RMS2AF080 Hardware User’s Guide...
Page 44
4. Remettez le cadenas en place et verrouillez-le afin de prévenir tout accès non autorisé à l'intérieur du système. 5. Rebranchez tous les cordons d'alimentation c. a. et câbles externes au système. Intel® Integrated RAID Module RMS2AF040 and RMS2AF080 Hardware User’s Guide...
1. Desbloquee y extraiga el bloqueo de seguridad de la parte posterior del sistema, si se ha instalado uno. 2. Extraiga y guarde todos los tornillos de las tapas.Extraiga las tapas. Intel® Integrated RAID Module RMS2AF040 and RMS2AF080 Hardware User’s Guide...
Il cavo è considerato il dispositivo d'interruzione dell'alimentazione principale (in c.a.). La presa alla quale si collega il sistema deve essere installata vicino all'unità e deve essere facilmente accessibile. Intel® Integrated RAID Module RMS2AF040 and RMS2AF080 Hardware User’s Guide...
Page 47
Se il sistema è stato a lungo in funzione, il microprocessore e il dissipatore di calore potrebbero essere surriscaldati. Fare attenzione alla presenza di piedini appuntiti e parti taglienti sulle schede e sul telaio. È consigliabile l'uso di guanti di protezione. Intel® Integrated RAID Module RMS2AF040 and RMS2AF080 Hardware User’s Guide...
® This Intel RAID Module has been evaluated for regulatory compliance as an Intel end system, and is included as part of the end system certification. For information on end system certification, refer to the product regulatory certification for the end system level product.