4.3 Calibrating the Header Sensors

Sensor calibration programs the windrower control module (WCM) with settings for the attached header.

4.3.1 Calibrating the Header Height Sensor

NOTE:
• The header MUST be attached to the windrower to perform this procedure. The cab display module (CDM)
automatically adjusts its programming for each header.
• The engine MUST be running to perform this procedure.
1. Turn ignition key to RUN, or start the engine.
2. Press PROGRAM (A) and SELECT (C) on cab display
module (CDM) to enter Programming Mode.
• WINDROWER SETUP? is displayed on the
upper line.
3. Press SELECT (C) until CALIBRATE SENSORS? is
displayed on the upper line.
• NO/YES is displayed on the lower line.
4. Press right (B) arrow to select Yes. Press SELECT (C).
• TO CALIBRATE SELECT is displayed in upper line.
5. Press left (A) or right (B) arrow until HEADER HEIGHT
is displayed on the lower line. Press SELECT (C).
• CALIBRATING HEIGHT is displayed on the
upper line.
• RAISE HEADER HOLD is displayed on the
lower line.
147764
CAB DISPLAY MODULE (CDM)
Figure 4.17: CDM Programming Buttons
Figure 4.18: Header Height Calibration
75