5-2 To install the machine
Install the brackets on the underside of the table board (see the illustration below).
Fit the rubber cushions onto the brackets.
Mount the machine head on the rubber cushions.
【6】TIMING OF THE LOOPER TO THE NEEDLE
6-1 To install the looper
Insert the looper to the proper depth and tighten screw
A.
DLR
series
7
6-2 Looper left-to-right movement
When the point of the looper, moving to the left or
right, has reached the center of the needle, the point
of the looper should be 2mm above the top of the
needle's eye. Adjustment is made by removing the
cover and loosening three screws A.
After this adjustment, tighten three screws A with
the same torque.
6-3 Looper setting distance
When the needle is at the bottom of its stroke and the
looper is at the extreme right end of its travel, adjust
distance A from the point of the looper to the right side
of the needle (see the table below).
Looper setting
Model
Distance A
1501~1504
3.5mm
1508、1509
3mm
■Adjustment is made by loosening screw C on lever B.
8
DLR
series