Updating Richauto Controller Software - Grizzly G0931 Owner's Manual

47" x 47" cnc router w/t-slot table
Table of Contents

Advertisement

6.
Use a multimeter to check continuity between
limit switches and interface board terminals
(see Figure 46).
— If continuity is confirmed between limit
switches and interface board, proceed to
Step 7.
— If continuity is not confirmed between limit
switches and interface board, repair wir-
ing, then repeat Steps 1–6.
Figure 46. Interface board limit switch input
wires.
7.
Swap faulty axis limit switch input wire on
interface board (see Figure 47) with any
one of the known good axes input wires
(X1=X-axis, X2=Y-axis, X3=Z-axis).
Z-Axis
Y-Axis
Figure 47. Interface board limit switch axes.
8.
Perform Steps 1–3 on Page 45 and verify
test results.
— If arrow does point up on axis swapped in
Step 7, replace faulty limit switch.
— If arrow does not point up on axis swapped
in Step 7, replace interface board.
-46-
Limit Switch
Input Wires
X-Axis
Updating RichAuto
Controller Software
If the RichAuto controller displays a blank screen,
the installed A11E software may need to be re-
installed to display correctly.
Contact Technical Support to have a soft-
ware update file sent directly to you. DO
NOT install unsupported software or the
controller may function erratically.
Items Needed
RichAuto A11E Software File (.PKG Format) .... 1
USB Drive 16GB or Less ................................... 1
IMPORTANT: DO NOT use a USB drive larger
than 16GB. The controller is designed to read
USB drives formatted below 16GB.
To update controller using USB drive:
1.
Copy software file (.PKG format) to USB
drive, then connect USB drive to controller.
2.
Press and hold OK button, then turn control-
ler ON.
Note: Update can be performed at the CNC
router, or by using the included USB-B cable
connected to a computer.
3.
When controller displays "Emergency State"
screen, scroll to "Update System" and press
OK button.
4.
At "SelectUpdateFile" screen, scroll to "UDisk
File" and press OK.
5.
Select .PKG update file and press OK.
6.
Once update is complete, restart controller.
7.
Verify machine parameters on controller
match those shown on Page 23.
Model G0931 (Mfd. Since 02/21)
Qty

Advertisement

Table of Contents
loading