Grizzly G0931 Owner's Manual page 26

47" x 47" cnc router w/t-slot table
Table of Contents

Advertisement

Verifying Voltage Parameters
The Voltage Setup screen enables opening or
closing of input and output signals to machine
components. The upper row of arrows represents
the input side, and the lower row represents the
output side (see Figure 19).
Voltage Parameters
1
2
3
4
1
2
3
4
Figure 19. Voltage parameter settings.
To verify voltage parameters:
1.
Press MENU on the controller, then scroll to
Machine Setup and press OK.
2.
Scroll to Voltage Setup and press OK to enter
voltage parameter screen.
3.
Verify arrows in voltage parameters match
the table in Figure 19.
— Arrow down indicates normally open circuit.
Arrow up indicates normally closed circuit.
Numbers 1–8 correspond to X1–X8 inputs
shown in Verifying Input Parameters on
this page.
4.
Press X+ or X- buttons to scroll left or right,
and Y+ or Y- to scroll up or down, and high-
light desired parameter.
5.
Press RUN/PAUSE to cycle arrow direction
up (normally closed) or down (normally open).
6.
Press OK to save changes and return to
menu screen.
-24-
5
6
7
8
5
6
7
8
Verifying Input Parameters
The input configuration screen shows electrical
inputs sent by various machine components dur-
ing operation (see Figure 20).
Input Parameters
X1:
Enable
X2:
Enable
X3:
Enable
X4:
Enable
X5:
Enable
X6:
Disable
X7:
Enable
X8:
Disable
Figure 20. Input parameter settings.
Failure to properly configure machine input
parameters may cause system errors.
To verify input parameters:
1.
Press MENU on the controller, then scroll to
Machine Setup and press OK.
2.
Scroll to Input Confi and press OK to enter
input configuration screen.
3.
Verify parameters in Input Confi match the
table in Figure 20.
4.
Press X+ or X- buttons to scroll up or down,
and highlight desired parameter.
5.
Press RUN/PAUSE to change setting.
6.
Press OK to save changes and return to
menu screen.
Model G0931 (Mfd. Since 02/21)
X-Axis Limit Switch
Y-Axis Limit Switch
Z-Axis Limit Switch
Tool Setter
Driver Alarm
Hard Limit
Emergency Stop
Pedal Switch

Advertisement