Intercode Delay - Datalogic QuickScan I QM2131 Product Reference Manual

General purpose handheld linear imager bar code reader
Table of Contents

Advertisement

Intercode Delay

Specifies the delay between labels transmitted to the host for this interface. The
selectable range for this feature is from 0 to 99 seconds.
Follow these instructions to set this feature:
1. Determine the desired setting.
2. Pad the number with leading zeroes to yield two digits. For example: 0 =
00, 5 = 05, 20 = 20, etc
3. Scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Program-
ming Mode.
4. Scan the bar code: SELECT INTERCODE DELAY SETTING.
5. Scan the appropriate two digits from the keypad in
represent the duration which was determined in the steps above. You will
hear a two-beep indication after the last character.
NOTE
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming
Mode.
This completes the procedure. See
this feature.
Table 14. Wedge Intercode Delay Examples
STEP
ACTION
1
Desired Setting
2
Pad with leading zero(es)
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT INTERCODE DELAY SETTING
Scan Two Characters From
5
Appendix D, Keypad
7
Scan ENTER/EXIT PROGRAMMING MODE
Product Reference Guide
If you make a mistake before the last character, scan the CANCEL bar
code to abort and not save the entry string. You can then start again
at the beginning.
EXAMPLES
No Delay
00
'0' and '0'
Appendix D,
Table 14
for some examples of how to set
5 Seconds
60 Seconds
05
60
'0' and '5'
'6' and '0'
Keyboard Wedge
Keypad, that
99 Seconds
99
'9' AND '9'
287

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Quickscan i qbt21x1Quickscan i qm21x1

Table of Contents