optris PI 200 Operator's Manual page 69

Hide thumbs Also See for PI 200:
Table of Contents

Advertisement

Software PIX Connect
1
IR image from the camera
2
Temperature profile: Shows the temperatures along max. 2 lines at any size and position in the image.
3
Reference bar: Shows the scaling of temperature within the color palette.
4
Temperature of measure area: Analyses the temperature according to the selected shape, e.g. average temperature of the
rectangle. The value is shown inside the IR image and the control displays.
5
Control displays: Displays all temperature values in the defined measure areas like Cold Spots, Hot Spots, temperature at
cursor, internal temperature and chip temperature.
Alarm settings: Bar showing the defined temperature thresholds for low alarm value (blue arrow) and high alarm value (red
arrow). The color of numbers within control displays changes to
(when temp. below the low alarm value).
6
Temperature time diagram: Shows the temperature curves over time for selectable region of interest (ROI)
7
Histogram: Shows the statistic distribution of single temperature values.
8
Automatic / manual scaling of the palette (displayed temperature range): Man., </> (min, max), 1σ : 1 Sigma, 3σ : 3 Sigma,
OPT: Palette optimization
9
Menu and Toolbar (Icons)
10
Icon enabling switching between color palettes
11
Status bar: Serial number, optic, temperature range, cursor position, device framerate/ display framerate, emissivity, ambient
temperature, flag status
red
(when temp. above the high alarm value) and to