Backward/Forward Compatibility With Older Software Versions - Cornelius VIPER E 2 FLAVOR Manual

Hide thumbs Also See for VIPER E 2 FLAVOR:
Table of Contents

Advertisement

!
WARNING:
In Step 1 in Table 86, disconnect electrical power from the unit. Failure to disconnect the power could result in serious
injury, death, or equipment damage.
Step
1
2
3
4
5
6
Mounting
Studs

Backward/Forward Compatibility with Older Software Versions

With version 3.0 software release several of the boards used to control the equipment will not be backward compatible
with boards containing version 2.x of the software. Please refer to the table below for compatibility.
Software Revision / Board Description
User Interface - UI
Input/Output - IO
Motor Control
Status
Language Chips
The user interface (UI) board and the input/output (I/O) board must have same software version for correct operation. If
the UI board and the IO board do not have the same software versions an error will be displayed on the UI. The error dis-
played will depend upon which board has 2.x software and has 3.x.Either "X BRL TEMP OUT" will be displayed or "H20
OUT" will be displayed followed 30 seconds later with "X BRL TEMP OUT". If either of these messages is displayed after
changing a control board check the software version. The current software version for each board can be found through the
menu screen. Select, MENU, UNIT DATA, then press the "VER" key. The control boards will also have a label marked with the
part number. A -100 suffix has been added to the part numbers for each of these boards to indicate version 3.0 software
release.
© 2022, Marmon Foodservice Technologies Inc.
Action
Disconnect power from the unit.
Connect a static strap to your wrist and any convenient chassis ground on the unit.
Unplug the eight (8) connectors from the control board.
Squeeze each of the mounting studs at the corners of the board while carefully lifting
the board.
Replace the board with a new board.
Reverse the procedure to install the new board.
Figure 82. View of Control Board in E-Box
V2.x Part Number
620314871S
620314869S
620314868S
620314874S
629096930XX
- 99 -
Viper Installation, Service & Decommissioning Manual
Table 86.
Table 87.
V3.x Part Number
620314871-100S
620314869-100S
620314868S
620314874S
629096931XX
Backward Compatibility
No
No
Yes
Yes
No
Publication Number: 620073146SER