Pitney Bowes FastPac DI950 Operator's Manual page 73

Hide thumbs Also See for FastPac DI950:
Table of Contents

Advertisement

Envelope
Options
(continued)
SV61311 Rev. E
Menu Item
Associated Options and Actions
Additional Settings
Double Detect allows the system sense when multiple envelopes
are fed unintentionally.
Feeder Type allows you to change the Feeder setting when
material is problematic.
NOTE: The Special Feeder is a purchasable option. If available,
it will be located at the top left or right of the Feeder Tower. It is
an option for one or more tower feeders to improve feeding of
thin prefolded items or booklets with thin covers. It reduces the
tendency of these items to separate while they are being fed. You
must push the "Special Feeder" lever up to run a job when the
Feeder Type is set to Special Feeder.
Feeder Linking allows multiple Feeders to feed the same
envelope.
NOTE: Feeders must be on the same module and on the same
side of the tower to be linked. For scanned items, always load
linked feeders at a collation break.
Double Detect Feature allows you to toggle:
-
Off means this feature will not function for this item, or
-
On means this feature is active.
Locaton allows you to toggle:
-
Default, or
-
Custom.
Custom Locaton for Top Edge allows you to enter a specific
measurement (distance from the edge feeding first into the
feeder) where the system should attempt to detect a double.
Set this option when Location is set to "Custom".
-
Use the UP/DOWN arrow keys to adjust the measurement
(in millimeters).
-
Select "Accept" when you are done.
NOTE: The double detect region cannot be within 25 mm of
the lead or trail edges of the envelope.
If the envelope s feedng from the HCEF, measure from the
bottom of the envelope.
If the envelope s feedng from the Feeder Tower, measure
from the top of the envelope. The custom location must be at
least 5 mm away from the edge of the window (if present), at
least 5 mm away from the edge of flap, and cannot lie on top
of a seam.
For best results, be sure to avod areas that overlap wth the
wndow, flap, or seams.
Acton On Double allows you to select where the items should
be fed to if a double is detected.
Normal is used for most items.
Specal Feeder helps problematic material run better.
None means there is no linking of Feeder Trays.
Two Feeders indicates that two Feeder Trays are linked and
feeding the same material.
Basic Operation • 3
3-31

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents