Troubleshooting

Due to the many features and functions of the meter,
it's possible that the setup of the meter does not
agree with what an operator expects to see. If the
meter is not working as expected, refer to the
Diagnostics menu and consult the recommendations
described below.

Diagnostics Menu (diag)

The Diagnostics menu is located in the Advanced
Features menu, to access Diagnostics menu see
Advanced Features Menu on page 43.
This menu allows the user to test the functionality of
all the meter LEDs, check the meter's software and
version information, and erase the MeterView Pro
software installation files from the meter. Press the
Enter button to view the settings and the Menu button
to exit at any time.
For a description of the diagnostic messages, see
Advanced Features Menu & Display Messages on
page 43.

Testing the Display LEDs

To test all LEDs on the display:
1.
Go to the Diagnostics menu (diAG) and
press Enter button.
2.
Press Up arrow button and scroll to
LED Test menu (led t)
3.
Press the Enter button to activate the LED
Test. The meter will cycle through all digits,
decimal points, and relay indicators to
enable the operator to check that all LEDs
are functioning properly.
4.
Press the Enter button again to access the
Information menu (info) or press the Menu
button to return to Run Mode.

Determining Software Version

To determine the software version of a meter:
1.
Go to the Diagnostics menu (diAG) and
press Enter button.
2.
Press Up arrow button and scroll to
Information menu (Info).
3.
Press Enter to access the software number
(SFT) and version (UER) information. Write
down the information as it is displayed.
Continue pressing Enter until all the
information is displayed.
4.
The meter returns to Run Mode after
displaying all the settings.

Reset Meter to Factory Defaults

When the parameters have been changed in a way
that is difficult to determine what's happening, it might
be better to start the setup process from the factory
defaults.
Instructions to load factory defaults:
1.
Enter the Advanced Features menu. See
Advanced Features Menu on page 43.
2.
Press Up arrow to go to Diagnostics menu
3.
Press and hold Right arrow for three seconds,
press Enter when display flashes reset.
Note: If Enter is not pressed within three
seconds, the display returns to the Diagnostics
menu.
4.
The meter goes through an initialization
sequence (similar as on power-up), and loads the
factory default settings.
50