Helios PD2-6100 Strain Gauge, Load Cell, and mV Meter

Advanced Features Menu

To simplify the setup process, functions not needed
for most applications are located in the Advanced
Features menu.
Press and hold the Menu button for three seconds to
access the advanced features of the meter.
Advanced Features Menu &
Display Messages
The following table shows the functions and
messages of the Advanced Features menu in the
order they appear in the menu.
Advanced Features Menu & Display Messages
Display
Parameter
filtEr
Filter
bypASs
Bypass
Round
Rounding
seriAl
Serial
SlaveId
Slave ID
baud
Baud rate
Tr dLY
Transmit delay
Parity
Parity
t-byt
Time byte
SelEct
Select
Functn
Input signal
conditioning
Linear
Linear
PV 1
PV1
PV 2
PV2
No PtS
Number of
points
Action/Setting
Set noise filter value
Set filter bypass value
Select rounding value
Set serial communication
parameters
Set slave ID or meter
address
Select baud rate
Set transmit delay for serial
communication
Select parity
Even, Odd, or None with 1
or 2 stop bits
Set byte-to-byte timeout
Enter the Select menu
(function, cutoff, out)
Linear, select number of
points
Set meter for linear
function and select number
of linearization points
Select PV1 number of
linearization points
Select PV2 number of
linearization points
Set PV1 for 2 to 32-point
linearization
Set PV2 for 2 to 8-point
linearization
43
Advanced Features Menu & Display Messages
Display
Parameter
SCALE
Scale
SCAL 1
Scale 1
SCAL 2
Scale 2
CutofF
Cutoff
Auto 0
Auto Zero
AoutPr
Analog output
programming
Source
Source
O-rang
Overrange
u-rang
Underrange
nmAx
Maximum
nmin
Minimum
Calib
Calibrate
4 nmA
4 mA output
20 nmA
20 mA output
user
User I/O
F1*
F1 function key
F4
F4 function
dI I
Digital input 1
dO 1
Digital output 1
ICal
Internal source
calibration
15nmV
15 mV
calibration
20nmV
20 mV
calibration
100nmV
100 mV
calibration
Instruction Manual
Action/Setting
Scaling parameter
Scaling parameter 1
Scaling parameter 2
Set low-value cutoff
Enter the Auto Zero
function (on/off)
Program analog output
parameters
Select source for the
4-20 mA output
Program mA output for
display overrange
Program mA output for
display underrange
Program maximum mA
output allowed
Program minimum mA
output allowed
Calibrate 4-20 mA output
(internal reference source
used for scaling the output)
Enter mA output value
read by milliamp meter
with at least 0.001 mA
resolution
Enter mA output value
read by milliamp meter
with at least 0.001 mA
resolution
Assign function keys and
digital I/O
Assign F1 function key
(*F1/F2/F3)
Assign F4 function
(digital input)
Assign digital input 1 – 4
Assign digital output 1 – 4
Enter internal source
calibration (used for
scaling the meter without a
signal source)
Calibrate 15 mV input
range (internal reference
source used for scaling the
input)
Calibrate 30 mV input
range (internal reference
source used for scaling the
input)
Calibrate 150 mV input
range (internal reference
source used for scaling the
input)