Power-On Configuration Key Sequences
Your PSR-600 features power-on keypress sequences that are
used as shortcuts to configuration items, like attenuator settings,
backlight settings and memory information. Power-on key
sequences are also used to place your scanner into firmware
upgrade mode for CPU and DSP firmware upgrades.
The following table lists the power-on key sequences available in
the PSR-600. Unless otherwise specified, each sequence is
invoked by pressing and releasing each key in sequence, one at
a time. The first key must be pressed while the Welcome/Owner
screen is being displayed:
Key Sequence
PSR-600 User Manual
Page
1
Shortcut to PGM>GLOB>Sound Mode
2
Shortcut to PGM>GLOB>Key Beeps
3
Displays Boot, CPU and DSP versions
DIM
Shortcut to PGM>GLOB>Light Mode
ATT
Shortcut to PGM>GLOB>Atten Mode
0, 0
Shortcut to PGM>GLOB>Memory Info
Destructive, clears working memory and
0, 1
resets all Global settings to factory
defaults. Does not affect V-Scanners.
Destructive, resets all Global settings to
0, 2
factory defaults. Does not affect working
memory or V-Scanners.
Destructive, executes EEPROM memory
test, then clears working memory and
0, 5
resets all Global settings to factory
defaults. Does not affect V-Scanners.
Erases DSP APP Upgrade code, restores
0, CLR
factory DSP version
Places radio in DSP APP firmware upgrade
0, PGM
mode
Function
93