Honeywell Silent Knight SK318PT Installation And Operation Manual page 169

Addressable fire system, emergency voice system
Table of Contents

Advertisement

Event Description
EVS Supervisory/Tamper Alarm
EVS Supervisory/Tamper Alarm
Restore
EVS Output Group Trouble
EVS Output Group Trouble
Restore
External Reset/Silence/Fire Drill
switch trouble
External Reset/Silence/Fire Drill
switch trouble restore
LOC Mic Activated EVS Alarm
LOC Mic Activated EVS Alarm
Restore
LOC/Point EVS # Alarm
LOC/Point EVS # Alarm Restore
Manual pull switch alarm
Manual pull switch alarm restore
Manual pull switch trouble
Manual pull switch trouble restore
Notification output trouble
Notification output trouble restore
Positive Alarm Sequence ac-
knowledge switch trouble
Positive Alarm Sequence ac-
knowledge switch trouble restore
SLC LED Module trouble
SLC LED Module trouble restore
Status Point Types Trouble
Status Point Types Trouble
Restore
Supervisory Detector Alarm
Supervisory Detector Alarm
Restore
Supervisory/Tamper Alarm
Supervisory/Tamper alarm condi-
tion restore
Supervisory/Tamper switch
trouble
Supervisory/Tamper switch
trouble restore
System-based AUX1 switch
alarm
6820 / 6820EVS Manual P/N LS10144-001SK-E:C 09/28/2017
SIA Reporting Format
SIA pi Modifier
Module
SIA
Parameter Fixed Length
ID # (If
Event
Any)
Codes
QS
0
QR
0
QT
Group #
+1000
QJ
Group #
+1000
UT
0000
UJ
0000
QA
0
QH
0
QA
Emergen-
cy #
QH
Emergen-
cy #
FA
Zone #
FH
Zone #
FT
Zone #
FJ
Zone #
FT
Group # +
1000
FJ
Group # +
1000
FT
Zone #
FJ
Zone #
ET
0000
ER
0000
UT
0
UJ
0
FS
Zone #
FR
Zone #
FS
Zone #
FR
Zone #
FT
Zone #
FJ
Zone #
UA
1000
Table 12.2 : Reporting Formats Table
Contact ID Reporting Format
SIA
Qualifier
Format NN -
panel ID
XX- SBUS ID
ZZZ- Zone #
PPPP- Point #
GGG- Group #
E- Emergency #
RRRR-Receiver #
QSNN000000
1
QRNN000000
3
QTNN001GGG
1
QJNN001GGG
3
UTNN000000
1
UJNN000000
3
QANN000000
1
QHNN000000
3
QANN0E0000
1
QHNN0E0000
3
FANN000ZZZ
1
FHNN000ZZZ
3
FTNN000ZZZ
1
FJNN000ZZZ
3
FTNN001GGG
1
FJNN001GGG
3
FTNN000ZZZ
1
FJNN000ZZZ
3
ETNN000000
1
ERNN000000
3
UTNN000000
1
UJNN000000
3
FSNN000ZZZ
1
FRNN000ZZZ
3
FSNN000ZZZ
1
FRNN000ZZZ
3
FTNN000ZZZ
1
FJNN000ZZZ
3
UANN001000
1
Event
Group #
Contact #
Code
241
00
000
241
00
000
320
00
Group #
320
00
Group #
373
00
000
373
00
000
220
00
000
220
00
000
220 +
00
000
Emer-
gency #
220 +
00
000
Emer-
gency #
115
00
Zone #
115
00
Zone #
373
00
Zone #
373
00
Zone #
320
00
Group #
320
00
Group #
373
00
Zone #
373
00
Zone #
333
00
000
333
00
000
379
00
000
379
00
000
200
00
Zone #
200
00
Zone #
200
00
Zone #
200
00
Zone #
373
00
Zone #
373
00
Zone #
140
01
000
165

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Silent knight 6820Silent knight 6820evs

Table of Contents