Gas Conversion and Specifications

Gas Specifications

- Australia
Main Burner Injector
Pilot Burner Injector
Low Fire Adjustment
High Fire Adjustment (*)
Burner Operating Pressure (**)
Supply Pressure
Gas Regulator Cap Screw
- New Zealand
Main Burner Injector
Pilot Burner Injector
Low Fire Adjustment
High Fire Adjustment (*)
Burner Operating Pressure (**)
Supply Pressure
Gas Regulator Cap Screw
(*) Gas Control Valve is fitted with a non adjustable maximum flow bypass blanking
screw.
(*) Measure burner operating pressure at the gas control valve outlet test point with
burner operating at 'High' setting.
appliance regulator and is not to be adjusted, apart from when carrying out gas
conversion, if required.
details).
Natural Gas
GP513
GP514
GP516
3.00mm
3.60mm
3.00mm
0.41
Maximum Flow Screw. Fully In c.w.
0.90 kPa
0.85 kPa
0.90 kPa
1.13 - 3.40 kPa
Natural Gas
GP513
GP514
GP516
3.00mm
3.60mm
3.00mm
0.41
Maximum Flow Screw. Fully In c.w.
0.90 kPa
0.85 kPa
0.90 kPa
1.13 - 3.40 kPa
Operating pressure is ex-factory set, through
(Refer to 'Gas Conversion' information in this section for
22
LP Gas (Propane)
GP518
GP513
GP514
2.85mm
1.80mm
2.10mm
1 Turn 'Out' c.c.w.
2.6 kPa
2.5 kPa
2.75 - 4.50 kPa
LP Gas
GP518
GP513
GP514
2.85mm
1.80mm
2.10mm
1 Turn 'Out' c.c.w.
2.6 kPa
2.5 kPa
2.75 - 4.50 kPa
GP516
GP518
1.80mm
1.70mm
0.25
2.6 kPa
GP516
GP518
1.80mm
1.70mm
0.25
2.6 kPa