Gas Connection - Blue Seal GP516 Installation And Operation Manual

Gas griddle
Table of Contents

Advertisement

- All Other Markets
Input Rating (N.H.G.C.)
Supply Pressure
Burner Operating Pressure (*)

Gas Connection

Input Rating (N.H.G.C.)
Supply Pressure
Burner Operating Pressure (*)
Gas Connection
(*) NOTE:
 (*) Measure burner operating pressure at at gas valve outlet test point with burner
operating at 'High Flame' setting.
 NAT, LPG & Butane Only - Operating pressure is ex-factory set and is not to be adjusted,
unless when converting between gases, if required.
 (**) TOWN GAS Only - Adjust burner operating pressure using adjustable gas regulator
supplied.
 Refer to 'Gas Conversion and Specifications' section in this manual for further details.
Gas Connection
Bench Models
Gas supply connection point is located at rear of appliance, approximately 130mm from right hand
side, 32mm from rear, 55mm from floor and is reached from rear of appliance. (Refer to
'Dimensions' section).
Connection is ¾" BSP male (For all other models).
All Other Models
Gas supply connection point is located at rear of appliance, approximately 130mm from right hand
side, 32mm from rear, 655mm from floor and is reached from beneath appliance. (Refer to
'Dimensions' section).
Connection is ¾" BSP male (For all other models).
Natural Gas
GP8450
GP8600
GP8900
40 MJ/hr
53 MJ/hr
80 MJ/hr 108 MJ/hr 40 MJ/hr
1.13 - 3.40 kPa
0.90 kPa
0.85 kPa
0.90 kPa
LP Gas (Propane)
GP513
GP514
GP516
40 MJ/hr
53 MJ/hr
80 MJ/hr 108 MJ/hr 40 MJ/hr
2.75 - 4.50 kPa
2.6 kPa
2.5 kPa
2.6 kPa
5
Specifications
Town Gas (**)
GP8120
GP8450
GP8600
53 MJ/hr
0.75 - 1.50 kPa
0.45 kPa
¾" BSP Male
Butane
GP518
GP513
GP514
53 MJ/hr
2.75 - 4.50 kPa
2.6 kPa
2.5 kPa
¾" BSP Male
GP8900
GP8120
80 MJ/hr 108 MJ/hr
GP516
GP518
80 MJ/hr 108 MJ/hr
2.6 kPa