Gas Specifications - Blue Seal Evolution GP514 Installation And Operation Manual

Evolution series gas griddle
Table of Contents

Advertisement

Gas Specifications

- Australia / New Zealand Only
Main Burner Injector
Pilot Burner Injector
Low Fire Adjustment
High Fire Adjustment
Operating Pressure
Supply Pressure
Gas Regulator Cap
Screw
- UK Only
Appliance Classification
Category:
Flue Type:
Main Burner Injector
Pilot Burner Injector
Low Fire Adjustment
High Fire Adjustment
Operating Pressure
Supply Pressure
Gas Regulator Cap
Screw
Note 1 The Gas Control Valve is fitted with a maximum flow bypass blanking screw, non
adjustable.
Note 2 The burner operating pressure is to be measured at the gas control valve outlet test point
(Refer to Fig 2) with one griddle burner operating at 'High' setting. The operating pressure
is ex-factory set, through the appliance regulator and not to be adjusted, apart from when
carrying out gas conversion, if required. (Refer to the 'Gas Conversion' section for details).
Gas Conversion and Specifications
Natural Gas
GP514
GP516
3.60mm
3.00mm
0.41
Maximum Flow Screw. Fully In c.w. (Note 1)
0.85 kPa
0.90 kPa
(Note 2)
(Note 2)
1.13 - 3.40 kPa
(4.5" - 13.5" w.c.)
II
2H3P.
A
1.
Natural Gas (G20)
GP514
GP516
3.40mm
3.00mm
0.41
Maximum Flow Screw. Fully In c.w. (Note 1)
8.5 mbar
8.2 mbar
(Note 2)
(Note 2)
20 mbar
23
LP Gas (Propane)
GP518
GP514
2.85mm
2.10mm
1 Turn 'Out' c.c.w.
2.5 kPa
(Note 2)
2.75 - 4.50 kPa
(11" - 18" w.c.)
Propane (G31)
GP518
GP514
2.85mm
2.10mm
1 Turn 'Out' c.c.w.
GP516
GP518
1.80mm
1.70mm
0.25
2.6 kPa
(Note 2)
GP516
GP518
1.80mm
1.70mm
0.25
26 mbar
(Note 2)
37 mbar

Advertisement

Table of Contents
loading

This manual is also suitable for:

Evolution gp516Evolution gp51Evolution series gp518