Gas Specifications
GP514
GP516
Main Burner
GP518
Pilot Injector
Low Fire Adjustment
High Fire Adjustment
GP514
Burner
Operating
GP516
Pressure
GP518
Supply Pressure
Gas Regulator Cap Screw
(*) NOTE:
Measure burner operating pressure at gas valve outlet test point with burner operating at
'High Flame' setting.
NAT, LPG & Butane Only - Operating pressure is ex-factory set, through the appliance
regulator and not to be adjusted, apart from when converting between gases, if required.
TOWN GAS Only - Burner operating pressure is to be adjusted using Town Gas adjustable
gas regulator supplied.
Refer to 'Gas Conversion and Specifications section in this manual for further details.
(*) - GP514 Town Gas model is available ex-factory on request only.
Gas Conversion and Specifications
Natural Gas
Ø 2.10mm
Ø 3.60mm
Ø 1.80mm
Ø 3.00mm
Ø 1.70mm
Ø 2.85mm
0.41
1 Full Turn Counter Clockwise from the 'Fully In' Position.
Maximum Flow Screw. Fully In c.w.
0.85 kPa
0.90 kPa
1.13 - 3.40 kPa
(4.5" - 13.5" w.c.)
21
LPG
Butane
Ø 1.95mm
Ø 1.65mm
Ø 1.55mm
0.25
0.25
2.5 kPa
2.6 kPa
2.75 - 4.50 kPa
(11" - 18" w.c.)
Town Gas (*)
Ø 7.20mm
Ø 5.50mm
Ø 5.20mm
0.75
3.5 kPa
0.63 kPa
0.75 - 1.50 kPa
(3" - 6" w.c.)
Adjustable Regulator
(Adjust to the Burner
Operating
Pressure specified)