Clearances; Assembly; Gas Connection - Blue Seal GP516 Installation And Operation Manual

Gas griddle
Table of Contents

Advertisement

Clearances

NOTE: Only non-combustible materials can be used in close proximity to this appliance.
Any gas burning appliance requires adequate clearance and ventilation for optimum and trouble-free
operation. The following minimum installation clearances are to be adhered to:
Left / Right Hand Side
Rear

Assembly

NOTE:
 All Models are delivered completely assembled. No further assembly is required.
 This appliance is fitted with adjustable feet to enable appliance to be positioned securely
and level. This should be carried out on completion of gas connection. Refer to 'Gas
Connection' section.
Optional Accessories (Refer to Replacement Parts List)
 Plinth Kit. For installation details, refer to instructions supplied with each kit.

Gas Connection

NOTE: ALL GAS FITTING MUST ONLY BE CARRIED OUT BY AN QUALIFIED PERSON.
1.
Blue Seal Gas Griddles do not require an electrical connection, as they function totally on gas supply
only.
2.
It is essential that gas supply is correct for appliance to be installed and that adequate supply
pressure and volume is available. The following checks should be made before installation:-
a. Gas Type the appliance has been supplied for is
shown on coloured stickers located above gas
connection and on rating plate. Check that this is
correct for gas supply, appliance is being installed for.
Gas conversion procedure is detailed in this manual.
b. Supply Pressure required for this appliance is
shown in 'Specifications' section of this manual.
Check gas supply to ensure adequate supply pressure
exists.
c. Input Rate of this appliance is shown on Rating
Plate, refer to 'Dimensions' section for rating plate
locations for different models. Input rate should be
checked against available gas supply line capacity.
Particular note should be taken if appliance is
being added to an existing installation.
NOTE: It is important that adequately sized piping runs directly to connection joint on appliance
with as few tees and elbows as possible to give maximum supply volume.
3.
Fit gas regulator supplied, into gas supply line as close to appliance as possible.
NOTE: Gas pressure regulator provided with this appliance is convertible between Natural Gas and
LPG as per 'Gas Conversion Section' in this manual.
Ensure regulator is converted to correct gas type that appliance will operate on.
Regulator outlet pressure is fixed ex-factory for gas type that regulator is converted to and
it is NOT to be adjusted.
Combustible Surface
50mm
50mm
11
Non Combustible Surface
0mm
0mm
Rating Plate Location
for Leg Stand Models
Installation
Fig 1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gp513Gp514Evolution seriesGp518

Table of Contents