Connect a voltmeter across the PMC #2 terminal and battery
negative.
Close all interlock switches, turn the Key Switch ON, and
place the F&R Switch in Forward.
Depress the accelerator pedal to engage MS-1 only.
If the voltage is not between 6.0 and 6.5 volts then
•
go to the Accelerator sequence.
Depress the pedal fully.
If the voltage is not between 11.0 and 11.5 volts then
•
go to the Accelerator sequence.
Connect voltmeter across the PMC KSI terminal and battery
negative.
With the pedal still fully depressed:
If the voltage is not at battery volts then go to the
•
Key Switch sequence.
If the voltage is at battery volts then continue with
•
the next test.
Curtis PMC Troubleshooting
The voltage shown is for illustration
only. The actual voltage may vary.
+
_
Main Battery
Negative
FLUKE 79
SERIES II MULTIMETER
The voltage shown is for illustration
OFF
V
Hz
only. The actual voltage may vary.
V
mV
Ω
A
+
−
Main Battery
Negative
B-
B+
KSI
#2
M-
A2
B-
B+
KSI
#2
M-
A2
Page 7