4. From inside the box disconnect wiring associated with the supply cord.
5. Install the new power supply cord by reversing steps 1-4.
REMOVAL OF BASKET LIFT BACK (OPTIONAL ACCESSORIES)
1. Remove all baskets and basket support racks from tank.
2. Drain appliance tank, disconnect unit power and tipping restraint. Move appliance to an area where the
back is completely accessible.
3. Remove the basket lift arm. (Fig.55)
4. Remove (14) screws from the upper back of the basket assembly using a 1/4" socket. (Fig. 56)
Fig. 55
Fig. 56