BULLET NOSE BURNER ORIFICE REPLACEMENT
1. Follow steps 1-8 under Replacement of Burner.
2. Disconnect the burner orifice top from bullet with a 5/16" wrench. The bullet body may be removed with
channel locks. (Figs. 43)
3. Install new orifice by reversing steps 1-2.
REMOVAL OF FILTER DISCARD TUBE(S) (FILTER INTER PLUMB BATTERY FRYERS)
1. Close all fryer drain ball valves.
2. Place a shortening discard pan under section of the inter plumb being disconnected.
3. With a 7/16" deep throat socket remove the discard tube clamp hardware and the
stainless steel collar. Retain all parts for reassembly. (Figs. 44)
Note: GR85 and some filter interplumb fryers are equipped with flange mounted discard tubes which
require the removal of (2) bolts and a gasket.
Figs. 43
Figs. 44