REMOVAL OF POWER SUPPLY BOX (ELECTRONIC IGNITION AND BASKET LIFT MODELS)
1. Disconnect gas line and pull out so that the back is accessible.
2. Disconnect the supply box wire harness (Fig. 47)
3. From the front of the unit follow steps 1-5 under Removal of ignitor assembly.
4. From rear of unit with 7/16" socket and wrench remove the (2) nuts and bolts holding the supply box to the
unit base frame. (Fig. 48) Note: In the GR25 fryer, the supply box is mounted vertically in the right rear
corner of the appliance. To lower the box remove the holding screw on the bracket.
Fig. 47
Fig. 48