Ex
Disconnect the
DO NOT disconnect
the network cable.
2.3.2 Wall Mounting
Before you start:
Make sure that the wall is thick enough to withstand the expansion screws.
Make sure that the wall is strong enough to withstand more than eight times the
weight of the dome and the accessories.
There must be enough space for installing the explosion-proof dome and its
accessories.
Make sure the speed dome is power off before connecting the cables.
Steps:
1.
Drill four screw holes for φ16 expansion screws in the wall, and fix the
installation plate onto the wall by inserting the four M12 × 130 expansion screws
into the wall. Make sure that
2.
Insert the flag washer and the spring washer. Then tighten the four screws to
secure the installation plate as shown in Figure 2-4.
168
Explosion-proof Dome·Quick Start Guide
cables
Figure 2-3 Disconnecting the cables
Cable Outlet
Figure 2-4 Install the Installation Plate
mark is upward.
6
Unit:mm