Cable Entry Installation - HIKVISION DS-2DF6C431-CX(T5/316L) Quick Start Manual

Explosion-proof dome
Hide thumbs Also See for DS-2DF6C431-CX(T5/316L):
Table of Contents

Advertisement

Ex
8.
Remove the protective film on the bubble after the installation is finished.

2.3.4 Cable Entry Installation

Purpose:
To ensure the explosion-proof performance of the speed dome, you shall route the
cable through the cable entry to protect the cables after speed dome installation.
Steps:
1.
Loosen and take off the gland nut of the cable entry.
2.
Seal the cable entry by routing the cables through the sealing ring, washer, and
gland nut in order as shown in Figure 2-16.
3.
Screw tight the gland nut to the base.
Explosion-proof Dome·Quick Start Guide
Figure 2-15 Secure the Bracket
Figure 2-16 Seal the Cable Entry
12
Explosion-proof
Junction Box (Optional)
Sealing
Ring Washer Gland Nut