Huawei TaiShan X6000 User Manual page 27

Hide thumbs Also See for TaiShan X6000:
Table of Contents

Advertisement

TaiShan X6000 Server
User Guide
No.
9
10
11
Issue 04 (2020-06-05)
Name
Description
HMM
Implements X6000 chassis management, including
temperature monitoring, fan management, power supply
management, and server node management.
PSU
Connect the PSUs, HMM, system backplane, and disk
backplane +
backplane, and provide power to the server.
system
power
copper strip
PSU
2 x 1500 W enhanced AC PSUs (compatible with 240
HVDC)
NOTE
● The X6000 PSUs support 1+1 redundancy mode only when the
server power is lower than that of a single PSU.
● If the input voltage is between 100 V and 120 V, the working
power of each PSU will decrease to 1000 W.
● If the input power is between 200 V and 240 V, or 240 V
HVDC, the working power is 1700 W.
Copyright © Huawei Technologies Co., Ltd.
2 Components
20

Advertisement

Table of Contents
loading

Table of Contents